摘要 通过对连续监测法检测血清中ALT测量过程的分析,确定并简化测量不确定度的来源;采用不确定度A类评定和不确定度B类评定方法,量化各不确定度分量;计算合成不确定度与扩展不确定度。当ALT=66.5 U/L时,连续监测法检测血清中ALT的扩展不确定度为U=3.81U/L(K=2,置信水平95%);在各不确定度分量中,由标准品所引入的测量不确定度分量所占比重最大。依据JJF1059-1999《测量不确定度评定与表示》可对连续监测法检测血清中ALT的测量不确定度进行合理评定。 To discuss the methods of estimation of uncertianty in measurement in detecting of ALT in serum by continuous monitoring procedure.To confirm and simplify the sources of uncertianties in measurement arising from analysing the process of the detection of ALT in serum by continuous monitoring procedure;Quantifying individual uncertainty components,which were combined to give a combined standard uncertainty and an expanded standard uncertainty.The expanded standard uncertainty of detecting of ALT in serum by continuous monitoring procedure can be reasonably estimated according to JJF1059 -1999.
出处 《检验检疫科学》 2009年第4期30-32,共3页 Inspection and Quarantine Science
关键词 不确定度 ALT 评定 Uncertianty ALT Estimation
  • 相关文献

参考文献4

二级参考文献22

  • 1王露楠,李金明,邓巍,郑怀竞.乙型肝炎病毒DNA聚合酶链反应测定室间质量评价[J].中华肝脏病杂志,2004,12(8):501-502. 被引量:4
  • 2李金明.聚合酶链反应临床应用的优越性和局限性[J].中华检验医学杂志,2005,28(3):225-227. 被引量:75
  • 3王治国,王薇,李小鹏.测量不确定度及其在临床检验中应用[J].中国卫生统计,2005,22(2):85-86. 被引量:57
  • 4GB/T15481—2000.检测和校准实验室能力的通用要求[S].[S].,..
  • 5JJF1059—1999.测量不确定度评定与表示[S].[S].,..
  • 6Guldeline to Expression of Uncertainty in Measurement. ISO/TAG 4/WG3, June 1993.
  • 7Quantifying Uncertatnty in analytical chemistry. Vision 6, Eurachem,March 1995.
  • 8The expression of Uncertainty in Quantltative Testing. EAL23 August 1996.
  • 9中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..
  • 10Kristiansen J. The guide to expression of uncertainty in measurement approach for estimating uncertainty: an appraisal [J]. Clin Chem,2003,49( 11 ) :1822.