基于CPLD的SF6浓度监测系统的设计 被引量:1

The Design of SF_6 Concentration Measurement System Based on CPLD Techniques
下载PDF
导出
摘要 为了对广泛用于高压系统(HV)灭弧断路器的SF6气体浓度进行实时监测,设计并实现了SF6气体浓度监测系统.阐述了超声波测量气体密度的原理.根据模块化设计思想,采用了CPLD和单片机实现了高精度、宽量程SF6气体浓度测量,并集成了湿度、温度、氧浓度和气压等参数的测量功能.实践证明该系统运行可靠,工作稳定,有效提高了测量精度. To detect the conce voltage (HV) system widely, the ntration of SF6 timely, which is used for arc control breaker in the high- SF6 concentration measurement system has been designed and implemen- ted. The principle of ultrasonic measurement for gas concentration is described. The CPLD and MCU are designed for detecting SF6 concentration in high-resolution and high-rangeability, and for collecting relative humidity (HR), temperature, oxygen concentration and air pressure. Practice indicates that the system has good performances such as high reliability, stability, high frequeney and precision.
出处 《徐州工程学院学报(自然科学版)》 CAS 2009年第2期56-60,共5页 Journal of Xuzhou Institute of Technology(Natural Sciences Edition)
关键词 CPLD 超声波 六氟化硫 灭弧断路器 高压系统 CPLD ultrasonic SF6 arc control breaker HV system