摘要
通过对阀门动作规律的恰当模拟,对武汉市某火电厂的冷却水循环系统的事故进行详尽的分析,找出了事故发生的原因,并对其今后的安全运行提供了良好的建议.
Through simulating the operation law of the valve which is of the cooling water circulating system of a thermal power plant in Wuhan city,accident analyses for this cooling water system are carried out.The reasons of the accident are also found out.Finally,some good proposals for the coming safety operation of the system are suggested.
出处
《武汉水利电力大学学报》
CSCD
1998年第4期6-9,共4页
Engineering Journal of Wuhan University
基金
中华电力教育基金会电力新星资助项目
关键词
冷却水
循环系统
水锤
事故分析
火电厂
cooling water
circulating system
water hammer
accident analysis