循环加热式空气源热泵热水器运行性能的试验研究 被引量:5

Experimental study of operating performance on air source heat pump water heater with cylic heating
下载PDF
导出
摘要 以套管式换热器作为热回收元件对循环加热式空气源热泵热水器的运行性能进行试验研究,指出:水箱水温从15℃升高到55℃时,系统参数如吸、排气压力,进、出水温度等随着水箱水温的变化而升高,同时系统的能耗也增大,而系统性能系数有所降低,在3.69左右,但与传统热水器相比系统还是节能的,是可行的. Using coaxial pipe heat exchanger as heat recovery components, the operating performance on air source heat pump water heater with cylic heating was studied. Based on the experiment results, with wa- ter tank temperature ranging from 15℃ to 55℃ ,the system parameters such as inlet, exhaust pressure, inlet and outlet water temperature rose, the coefficient of performance was about 3.69 and showed the feasibility of this system.
出处 《郑州轻工业学院学报(自然科学版)》 CAS 2009年第4期71-74,共4页 Journal of Zhengzhou University of Light Industry:Natural Science
关键词 热泵热水器 循环加热 节能 heat pump water heater cylic heating energy-saving
  • 相关文献

参考文献1

二级参考文献4

  • 1吴业正 韩宝琪.制冷原理与设备[M].西安:西安交通大学出版社,1987..
  • 2Minsung Kim,Min Soo Kim,Jae Dong Chung.Transient thermal behavior of a water heater system driven by a heater pump[J].International Journal of Refrigeration,2004,27:415-421.
  • 3岳孝方,陈沛霖.空调与制冷技术手册[M].同济大学出版社,1990.
  • 4Morrison G L,Anderson T,Behnia M.Seasonal performance rating of heat pump water heaters[C].ISES2001 Solar World Congress.

共引文献38