微种植体支抗即刻和早期加载的电镜观察 被引量:6

Scanning electron microscopic observation of immediate and early loading of mini-screw implants
下载PDF
导出
摘要 目的研究不同加载时间及加载力值对微钛螺纹钉种植体-骨结合界面的影响。方法选取5只Beagle犬建立实验动物模型,分别在左、右两侧上颌牙槽骨内植入微钛螺纹钉种植体各9枚。采用恒定力值为100 g及300 g的镍钛螺旋拉簧,分别在即刻、第2、4、8周对两侧种植体加载,对照组不加力。于第20周处死动物,取含微钛螺纹钉及其周围2 mm组织块,采用扫描电镜观察骨结合的状态。结果分别对不同加载力值及加载时间各组的扫描电镜图片进行对比观察,各组种植体-骨结合界面在形态学上均无显著性差异,均表现为:种植体与周围骨质结合良好,表面有大量骨质覆盖。种植体与其周围骨质间存在微小间隙,间隙均小于0.85 mm。结论微钛螺纹钉种植体即刻加载300 g以内的水平力不影响支抗种植体的稳定性。 Objective To evaluate the effects of the various timing and loading force on osseointegration interface of titanium mini-screw implants. Methods In 5 Beagle dogs, 9 titanium mini-screw implants were installed on each side of maxilla. The implants were loaded by using NiTi-screw extension springs with 100 g or 300 g constant force immediately, and at week 2, week 4 and week 8, respectively. Control groups were unloaded. At week 20, animals were sacrificed and specimens were prepared containing the mini-screw implants and 2 mm surrounding tissue. Osseointegration was observed by scanning electron microscope (SEM). Results A comparative analysis on SEM images from groups with different loading forces and time was performed. The implant osseointegration interface of different groups showed no significant morphological differences, demonstrating solidly the bonded interfaces of implants and surrounding bones, as well as bone covered surfaces of implants. Micro-gaps were less than 0.85 mm between mini-screw implants and bone tissue. Conclusion Immediate loading application of the titanium mini-screw implants with less than 300 g force does not influence the stability of implant anchorage.
出处 《同济大学学报(医学版)》 CAS 2009年第4期54-57,共4页 Journal of Tongji University(Medical Science)
关键词 微种植体 即刻加载 骨结合 种植体支抗 mini-screw Implant immediate loading osseointegration implant anchorage
  • 相关文献

参考文献10

  • 1Ohashi E, Pecho OE, Moron M, et al. Implant vs screw loading protocols in orthodontics[J] .Angle Orthod, 2006,76(4) :721 -727.
  • 2严拥庆,高益鸣,钱玉芬.支抗种植体的组织学研究进展[J].上海口腔医学,2006,15(6):668-671. 被引量:4
  • 3Saito S, Sugimoto N, Morohashi T, et al. Endosseous titanium implants as anchors for mesiodistal tooth movement in the Beagle dog[ J ]. Am J Orthod Dentofacial Orthop,2000,118 (6) : 601 - 607.
  • 4Liou EJ, Pai BC, Lin JC. Do miniscrews remain stationary under orthodontic forces? [J]. Am J Orthod Dentofacial Orthop ,2004,126 ( 1 ) :42 - 47.
  • 5Schnelle MA, Beck FM, Jaynes RM, et al. A radiographic evaluation of the availability of bone for placement of miniscrews[J]. Angle Orthod, 2004,74 (6) :832 -837.
  • 6吴晶,白玉兴,王邦康,高晓辉.微型种植体支抗愈合期稳定性的比较[J].中华口腔医学杂志,2006,41(4):226-227. 被引量:21
  • 7Meyer U, Joos U, Mythili J, et al. Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants [J ]. Biomaterials, 2004,25(10) : 1959 - 1967.
  • 8Freire JN, Silva NR, Gil JN, et al. Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage[ J].Am J Orthod Dentofacial Orthop ,2007,131 (6) :704e1 - 704e9.
  • 9Gallas MM, Abeleira MT, Fernandez JR, et al. Three- dimensional numerical simulation of dental implants as orthodontic anchorage [J ]. Eur J Orthod, 2005,27 ( 1 ) : 12 - 16.
  • 10康非吾,卢军,潘可风.种植区骨皮质厚度对种植体骨界面应力分布的影响[J].同济大学学报(医学版),2006,27(1):31-33. 被引量:23

二级参考文献46

  • 1马俊青,王林,张卫兵,王震东,严斌.微型支抗种植体即刻加载的组织学研究[J].口腔医学,2005,25(5):267-269. 被引量:32
  • 2吴晶,白玉兴,王邦康,高晓辉.微型支抗种植钉愈合期骨结合状态的组织学观察[J].北京口腔医学,2005,13(4):228-230. 被引量:35
  • 3Sevimay M,Turhan F,Kilicarslan MA,et al.Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown[J].J Prosthet Dent,2005,93(3):227-234.
  • 4Glauser R,Ruhstaller P,Windisch S,et al.Immediate occlusal loading of Branemark System TiUnite implants placed predominantly in soft bone:4-year results of a prospective clinical study[J].Clin Implant Dent Relat Res,2005,7(1):S52-59.
  • 5Porter JA Jr,Petropoulos VC,Brunski JB.Comparison of load distribution for implant overdenture attachments[J].Int J Oral Maxillofac Implants,2002,17(5):651-62.
  • 6Gillies RM,Morberg PH,Bruce WJ,et al.The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem[J].Med Eng Phys,2002,24(2):109-114.
  • 7Ivanoff CJ,Grondahl K,Bergstrom C,et al.Influence of bicortical or monecortical anchorage on maxillary implant stability:a 15-year retrospective study of banemark system implants[J].Int J Oral Maxillofac Implants,2000,15(1)103-107.
  • 8Stanford CM,Brand RA.Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling.J Prosthet Dent,1999,81:553-561.
  • 9Deguchi T,Takano-Yamamoto T,Kanomi R,et al.The use of small titanium screws for orthodontic anchorage.J Dent Res,2003,82:377-381.
  • 10Branemark R,Ohmell LO,Nilsson P,et al.Biomechanical characterization of osseointegration during healing:an experimental in vivo study in the rat.Biomaterials,1997,18:969-978.

共引文献43

同被引文献92

引证文献6

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部