期刊文献+

High-intensity focused ultrasound with large scale spherical phased array for the ablation of deep tumors 被引量:4

High-intensity focused ultrasound with large scale spherical phased array for the ablation of deep tumors
原文传递
导出
摘要 Under some circumstances surgical resection is feasible in a low percentage for the treatment of deep tumors. Nev-ertheless, high-intensity focused ultrasound (HIFU) is beginning to offer a potential noninvasive alternative to conventional therapies for the treatment of deep tumors. In our previous study, a large scale spherical HIFU-phased array was developed to ablate deep tumors. In the current study, taking into account the required focal depth and maximum acoustic power output, 90 identical circular PZT-8 elements (diameter=1.4 cm and frequency=1 MHz) were mounted on a spherical shell with a radius of curvature of 18 cm and a diameter of 21 cm. With the developed array, computer simulations and ex vivo experiments were carried out. The simulation results theoretically demonstrate the ability of the array to focus and steer in the specified volume (a 2 cm×2 cm×3 cm volume) at the focal depth of 15 to 18 cm. Ex vivo experiment results also verify the capability of the developed array to ablate deep target tissue by either moving single focal point or generating multiple foci simultaneously. Under some circumstances surgical resection is feasible in a low percentage for the treatment of deep tumors. Nevertheless, high-intensity focused ultrasound (HIFU) is beginning to offer a potential noninvasive alternative to conventional therapies for the treatment of deep tumors. In our previous study, a large scale spherical HIFU-phased array was developed to ablate deep tumors. In the current study, taking into account the required focal depth and maximum acoustic power output, 90 identical circular PZT-8 elements (diameter=1.4 cm and frequency=l MHz) were mounted on a spherical shell with a radius of curvature of 18 cm and a diameter of 21 cm. With the developed array, computer simulations and ex vivo experiments were carried out. The simulation results theoretically demonstrate the ability of the array to focus and steer in the specified volume (a 2 cm×2 cm×3 cm volume) at the focal depth of 15 to 18 cm. Ex vivo experiment results also verify the capability of the developed array to ablate deep target tissue by either moving single focal point or generating multiple foci simultaneously.
出处 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2009年第9期639-647,共9页 浙江大学学报(英文版)B辑(生物医学与生物技术)
基金 supported by the National Natural Science Foundation of China (No. 30800246) Shanghai Key Technologies R&D Programof China (No. 09441900500)
关键词 高强度聚焦超声 肿瘤治疗 消融 阵列 中国气象局 球形 震源深度 体外实验 High-intensity focused ultrasound (HIFU), Spherical phased array, Large scale, Deep tissue ablation
  • 相关文献

参考文献2

二级参考文献3

  • 1Wang Hong,IEEE Transactions Ultrasonics Ferroelectrics Frequency Control,1991年,38卷,5期,521页
  • 2J. W. Valvano,J. R. Cochran,K. R. Diller.Thermal conductivity and diffusivity of biomaterials measured with self-heated thermistors[J].International Journal of Thermophysics.1985(3)
  • 3李国伟,陈亚珠.不等间距排列的球面高强度聚焦超声相控阵列[J].声学学报,2001,26(2):117-120. 被引量:29

共引文献4

同被引文献7

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部