期刊文献+

施工现场高性能混凝土柱早期自收缩试验研究

Early-age autogenous shrinkage experimental study of high performance concrete column under construction-site conditions
原文传递
导出
摘要 使用埋设型KM系列应变传感器成功监测了处于模拟施工现场环境下,高性能混凝土柱早期自收缩变形特性,特别是混凝土浇注后24h的自收缩变形情况。从试验结果看,硬化前后24h高性能混凝土的自收缩变形增长最快,绝对变形值也比较大,24h自收缩值超过14d自收缩变形量的70%;而配筋混凝土试件由于配筋形成的钢骨架对自收缩的约束作用,其自收缩变形小于同等条件的素混凝土试件。监测和分析高性能混凝土结构早期的自收缩变形将对减少结构微裂纹、提高结构的稳定性有重要意义。 The early-age autogenous shrinkage of HPC column under construction-site conditions is monitored successfully, especially the first 24-hour deformation just after casting by KM-100B strain transducer. The experimental results show that HPC autogenous shrinkage rapidly increases within first 24 hours just after HPC casting, and first-day autogenous shrinkage is 70% larger than the total one within 14 days. And the autogenous shrinkage of reinforced specimen is smaller than that of plain specimen due to restraint of reinforcing frame. Monitoring and analyzing early-age autogenous shrinkage of HPC will give significant reference to study the durability and permeability of HPC structures.
出处 《建筑结构》 CSCD 北大核心 2009年第8期63-65,共3页 Building Structure
基金 洛阳理工学院人才引进科研基金资助
关键词 高性能混凝土 早期自收缩 埋设型应变传感器 high performance concrete early-age autogenous shrinkage embedded stain transducer
  • 相关文献

参考文献9

  • 1TAZAWA E, MIYAZAWA S. Autogenous shrinkage of concrete and its importance in concrete technology [ C]// Creep and Shrinkage of Concrete. Proceedings of the 5th International RILEM. London: Symposium, E & FN Spon, 1993: 59-168.
  • 2AICTIN P C, NEVILLE A M, ACKER P. Integrated view of shrinkage deformation[J]. Concrete International, 1997, 19 (9) : 35-41.
  • 3AICTIN P C.Autogenous shrinkage measurement [ G]//Autogenous Shrinkage of Concrete.E & FN Spon, 1999: 257-268.
  • 4贠英伟,张广峻,张百岁,Jang II-Young,王帅.FBG传感器监测高性能混凝土早期特性的试验研究[J].混凝土,2008(5):124-127. 被引量:5
  • 5朱永,陈伟民,封君,石荣,黄尚廉.混凝土固化期收缩应变监测的光纤珐珀传感器[J].土木工程学报,2001,34(5):24-28. 被引量:15
  • 6I1 YOUNG JANG, et al. The short term property monitoring for HPC columns by embedded FBG sensor [ J]. Annual Report of Institute of Industrial Technology Kumoh National of Technology, 2007, 22:31-42.
  • 7GB/T50081--2002普通混凝土力学性能试验方法标准[S].北京:中国建筑工业出版社,2002.
  • 8HEDLUND H. Stresses in High Performance Concrete due to Temperature and Moisture Variations at Early Ages [ D ]. Lulea, Sweden : Lulea University of Technology, 1996.
  • 9BYFORS J. Plain Concrete at Early Ages [ R ]. Swedish Cement and Concrete Research Institute Report, 1980.

二级参考文献17

  • 1周智,李冀龙,欧进萍.埋入式光纤光栅界面应变传递机理与误差修正[J].哈尔滨工业大学学报,2006,38(1):49-55. 被引量:46
  • 2袁迎曙.钢筋混凝土结构局部补强的收缩应力分析[J].土木工程学报,1996,29(1):33-40. 被引量:18
  • 3李鸿猷.城市建筑工程质量通病分析与防治530问[M].成都:四川科技出版社,1988..
  • 4Zhu Yong,Int Conference on Health Monitoring of Civil Infrastructure Systems,1999年,137页
  • 5谢尊渊,建筑施工,1998年
  • 6李鸿猷,城乡建筑工程质量通病分析与防治530问,1988年
  • 7张国顺,光纤传感技术,1988年
  • 8AITCIN P C,NEVILLE A M,ACKER P.Integrated view of shrinkage deformation,Concr.Int.,1997,19 (9):35-41.
  • 9MIYAZAWA TS.Autogenous shrinkage of concrete and its importance in concrete technology,in:Z.P.Bazant,L.Carol (Eds.),Creep and Shrinkage of Concrete,Proceedings of the 5th International RILEM Symposium,E & FN Spon,London,1993:59-168.
  • 10AICTIN P C.Autogenous shrinkage measurement,Autagenous Shrinkage of Concrete,edited by Tazawa,E.,E & FN Spon,1999:57-268.

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部