20碳钢在三元复合驱溶液中的腐蚀行为 被引量:8

CORROSION BEHAVIOUR OF MILD STEEL IN TRIAXIAL COMPOSITE FLOODING SOLUTION
下载PDF
导出
摘要 采用电化学测试技术与XPS技术,研究了20碳钢在三元复合驱溶液中的电化学行为及钝化膜的组成与结构。结果表明,20碳钢在三元复合驱溶液中发生钝化,形成的钝化膜组成为:Fe_3O_4、FeOOH、Fe_2O_3和Fe(OH)_2,其厚度约为7nm,铁元素价态沿钝化膜深度变化,由表面+3价到近基体内表面+3价与+2价并存。 Mild steel (0.24wt% C) can be passivated in triaxial composite flooding solution containing 1.2% NaCl+ 0.6% petroleum sulfonate + 0.12% polyacrylamide(wt%). The composition and structure of passive film formed on the steel were investigated by XPS. The results showed that the passive film was composed of Fe3O4, FeOOH, Fe2O3 and Fe(OH)2, and its thickness was about 7nm. The valence of elemental iron varied at different depth of the passive film. At the outer surface of the passive film, the valence of iron was +3, and at the interface near the matrix, +3 and +2 iron were detected.
出处 《中国腐蚀与防护学报》 CAS CSCD 1998年第3期203-208,共6页 Journal of Chinese Society For Corrosion and Protection
关键词 碳钢 三元复合驱溶液 钝化膜 XPS 腐蚀 采油 Mild steel, Triaxial composite flooding solution, Passive film, XPS
  • 相关文献

参考文献3

  • 1项民,硕士学位论文,1996年
  • 2吴文祥,大庆石油学院学报,1995年,19卷,119页
  • 3童育英(译),提高石油采收率,1989年,1页