摘要 采用英国Process Tomography有限公司研制的12电极双面电容层析成像(ECT)系统,研究了不同的分布器结构对鼓泡床气泡行为的影响。结果表明:在相同的表观气速下,随着分布器开孔数目的增多,气含率相应增加;随着表观气速的增加,气含率逐渐上升;当分布器具有泡罩结构时,对应的气含率较高。借助Plot3d考察了气泡上升过程中的准三维结构,发现气泡(群)的上升过程近似一种螺旋运动。 The twin-plane 12-electrode ECT(Electrical Capacitance Tomography) from Process Tomography Limited (UK) was employed to investigate the effect of different gas spargers on bubble behavior in a bubble column. The gas holdup increases with the increase of the number of orifices in the sparger and the superficial gas velocity. When the sparger has a bubble cap, the gas holdup becomes high. The quasi- 3d flow structure of bubbles was observed using Plot3d which showed that the bubbles perform a spiral motion along the wall.
出处 《华东理工大学学报(自然科学版)》 CAS CSCD 北大核心 2009年第1期1-4,共4页 Journal of East China University of Science and Technology
基金 国家自然科学基金(20876043) 上海市科委07DJ14002项目资助
关键词 电容层析成像 气含率 准三维图像 气体分布器 electrical capacitance tomography gas holdup quasi-3d image gas sparger
  • 相关文献

参考文献12

  • 1Haque M W,Nigam K D P,Joshi J B.Optimum gas sparger design for bubble columns with a low height-to-diameter ratio[J].Chemical Engineering Journal,1986,33:63-69.
  • 2Dhotre M T,Joshi J B.Design of a gas distributor:Three-dimensional CFD simulation of a coupled system consisting of a gas chamber and a bubble column[J].Chemical Engineering Journal,2007,125:149-163.
  • 3Bahadori F,Rahimi R.Simulations of gas distributors in the design of shallow bubble column reactors[J].Chem Eng Technol,2007,30(4):443-447.
  • 4彭黎辉,陆耿,张宝芬,廖延彪.电容成像技术及其应用[J].影像技术,2005,17(2):12-17. 被引量:3
  • 5王丽雅,庄华洁,宋景祯,陈斌,李希.高气速下鼓泡塔中气含率分布的测定[J].化学反应工程与工艺,2006,22(1):1-6. 被引量:8
  • 6靳海波,杨索和,佟泽民.γ射线透射技术测量气液鼓泡塔内气含率的轴向分布[J].化工学报,2004,55(9):1523-1527. 被引量:7
  • 7孙楠,黄民,祁志生.用于电容层析成像系统的电容测量电路[J].北京机械工业学院学报,2006,21(2):17-20. 被引量:3
  • 8Warsito W,Fan L S.ECT imaging of three phase fluidized bed based on three-phase capacitance model[J].Chemical Engineering Science,2003,58:823-832.
  • 9Warsito W,Fan L S.Measurement of real-time flow structures in gas-liquid and gas-liquid-solid flow systems using electrical capacitance tomography(ECT)[J].Chemical Engineering Science,2001,56:6455-6462.
  • 10Warsito W,Fan L S.Neural network multi-criteria optimization image reconstruction technique (NN-MOIRT) for linear and non-linear process tomography[J].Chemical Engineering and Processing,2003,42:663-674.

二级参考文献77

  • 1李国娜,王保良,黄志尧,李海青.电容层析成像中电容检测方法的分析比较[J].仪器仪表学报,2005,26(z2):730-731. 被引量:5
  • 2陆耿,彭黎辉,姚丹亚,张宝芬.电容层析成像系统的实用化设计[J].计量学报,2004,25(3):241-243. 被引量:12
  • 3丁富新,李飞,袁乃驹.环流反应器的发展和应用[J].石油化工,2004,33(9):801-807. 被引量:54
  • 4高彦丽,杨蓓,邵富群,章勇高.用于ECT系统的低成本、宽带微小电容测量电路[J].电测与仪表,2004,41(9):29-32. 被引量:9
  • 5张同旺,靳海波,何广湘,佟泽民,朱建华.加压大型鼓泡床反应器内大小气泡气含率研究[J].化学工程,2004,32(5):29-33. 被引量:9
  • 6[1]Dragmir B Bukur, James G Daly,Snehal A Patel. Application of γ-Ray Attenuation for Measurement of Gas Holdups and Flow Regime Transition in Bubble Columns.Ind.Eng.Chem.Res., 1996,35:70-80
  • 7[2]Zhang Tongwang(张同旺),Jin Haibo(勒海波),He Guangxiang(何广湘),Yang Suohe(杨索和),Tong Zemin(佟泽民).The Measurement in Bubble Column with DGD Method.Journal of Chemical Industry and Engineering (China) (化工学报),2000,55(3):476-480.
  • 8[3]Men Zhuowu (门卓武),Que Guohe(阙国和),Arsam B,Morsi B I.Effect of Operating Variables on Hydrodynamics in Large Scale Slurry Bubble Column Reactor.Journal of Chemical Industry and Engineering (China) (化工学报),2002,53(1):4-10
  • 9[4]Calderbank P H, Evans F,Rennie J. The Mass-Transfer Efficiency of Distillation and Gas Absorption Plate columns.Inst.Chem.Eng.London, 1961(125):51-58
  • 10[5]Shollenberger K A, Torczynski J R, Adkins D R,O'Hem T J,Jackson N B.Gamma-sensitometry Tomography of Gas Holdup Spatial Distribution in Industrial Scale Bubble Columns.Chem.Eng.Sci., 1997,52(3):2037-2048

共引文献29

同被引文献16

引证文献1

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部