期刊文献+

基于IMS技术的多功能爆炸物/毒品探测仪的研制 被引量:1

The development of multifunctional exploder/drug detector based on IMS technique
下载PDF
导出
摘要 介绍了多功能爆炸物/毒品探测仪的设计与实现。该仪器采用IMS(Ion Mobility Spectrometry)技术,实现阴、阳离子双模式的定性分析,用于安检场合的对常见毒品和爆炸物的探测。 The design and realization of multi-functional Drug/Explosive Detector based on the IMS theory are introduced in this article. By application on dual-mode (i.e. anion and cation), this detector can test common contrabands like drug and explosive. The Drug/ Explosive Detector can be equipped at certain entry of security inspection.
出处 《自动化与仪器仪表》 2009年第5期107-109,共3页 Automation & Instrumentation
关键词 离子迁移技术 毒品 爆炸物 双模式 IMS Drug Explosive Dual-mode
  • 相关文献

参考文献10

  • 1杨斌.浅析当前毒品犯罪与恐怖活动结合的趋势及应对措施[J].云南警官学院学报,2009(2):71-74. 被引量:6
  • 2Eiceman G. A., Karpas Z.. Ion Mobility Spectrometry (ist Edition) [M].Boca Raton, CRC Press, 1994.
  • 3吕勇杰,朱学梅,郑健,陈扬骎.应用离子迁移率谱仪技术快速检测毒品的研究[J].核技术,2007,30(10):818-822. 被引量:8
  • 4H. H. Herbert, F.S. William, H.S.L. Robert, Anal. Chem., 62, 1208A (1990).
  • 5G. W. Griffin, I. Dzidic, D.I. Carroll, R.N. Stillwell, E.C. Horning, Anal. Chem., 45, 1204 (1973).
  • 6朱丽英,蔡家楣,郑健.离子迁移谱仪嵌入式系统的设计[J].工业仪表与自动化装置,2004(3):67-69. 被引量:3
  • 7Ochoa M L., Harrington P. B.. Detection of methamphetamine in the presence of nicotine using in situ chemical derivatization and ion mobility spectrometry [J]. Anal. Chem., 2004, 76, 985-991.
  • 8Lawrence A. H.. Ion mobility spectrometry/mass spectrometry of some prescription and illicit drugs [J], Anal. Chem., 1986, 58(6):1269-1272.
  • 9Karasek F. W., Hill H.H. Jr., Kim S.H.. Plasma chromatography of heroin and cocaine with mass-identified mobility spectra [J]. J. Chromatogr., 1976,117(2): 327-336.
  • 10Ewing R. G., Atkinson D. A., Eiceman G.A,,Ewing G.J..A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds [J].Talanta, 2001,54:515-529.

二级参考文献12

  • 1G.A.Eiceman.Ion-mobility spectrometry as a fast monitor of chemical composition[J].trends in analytical chemistry 2002,21(4):259. .
  • 2Revercomb H E,Mason E A.Anal Chem,1975,47(7):970-983.
  • 3Ochoa M L,Harrington P B.Anal Chem,2004,76:985 -991.
  • 4Siems W F,Ching Wu,Tarver E E,et al.Anal Chem,1994,66(23):4195-4201.
  • 5Spangler G E.International Journal of Mass Spectrometry,2002,220:399 -418
  • 6Eiceman G A,Karpas Z.Ion Mobility Spectrometry,USA:CRC Press,1994.
  • 7Lawrence A H.Anal Chem,1986,58(6):1269 - 1272.
  • 8Matz L M,Hill H H.Anal Chem,2001,73(8):1664-1669.
  • 9Steiner W E,Clowers B H,Fuhrer K,et al.Rapid Commun Mass Spectrum,2001,15:2221 -2226.
  • 10Matz L M,Hill H H.Anal Chem,2002,74(2):420-427.

共引文献14

同被引文献11

  • 1袁曦,郑健,施亮,蒋大真.用于现场痕量检测的IMS爆炸物探测仪研究[J].核技术,2006,29(7):544-547. 被引量:16
  • 2王学峰,叶伟,彭凤武.离子迁移谱技术及其在化学战剂侦检中的应用[J].化学分析计量,2007,16(4):76-79. 被引量:6
  • 3Eiceman GA, Karpas Z. Ion mobility spectrometry[M]. Florida, USA: CRC Press, 1994.
  • 4Ewing RG, Atkinson DA, Eiceman OA, Ewing GJ.. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds[J], Talanta, 2001, 54: 515-529.
  • 5Lawrence AH. Ion mobility spectrometry/Mass spectrom- etry of some prescription and illicit drugs[J].Anal. Chem., 1986, 58: 1269-1272.
  • 6Sferopoulos R.. A review of chemical warfare agent(CWA) detector technologies and conlnercial-off-the-shelf items [M].Victoria, Australia: Defence Science and Technology Organisation (DSTO), 2008.
  • 7Ewing RG., Atkingon DA., Eiceman GA., Ewing GJ.. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds Talanta 2001, 54:515-529.
  • 8Chen C., Dong C., Du YZ., Cheng SS., Han FL., LL., Wang WG., Hou KY., Li HY.. Bipolar Ionization Source for Ion Mobility Spectrometry Based on Vacuum Ultraviolet Radia- tion Induced Photoemission and Photoionization[J].Anal. Chem., 2010, 82(10): 4151-4157.
  • 9Salcedo D., Villalta PW., Varutbangkul V., Wormhoudt JC., Miake-Lye RC., Worsnop DR., Ballenthin JO., Thorn WF., Viggiano AA., Miller T~, Flagan RC., Seinfeld JH.
  • 10Effect of relative humidity on the dioxide and sulfuric acid using a mass spectrometer[J].Int. J. Mass 17-30. detection of sulfur chemical ionization Spectrom. 2004,231.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部