由替考拉宁手性固定相(TECSP)制备出了一种新型的高效液相色谱手性固定相:间甲基苯基异氰酸酯替考拉宁手性固定相(TI-TECSP).在反相流动相中用7种氨基酸和3种非氨基酸化合物对这两种手性固定相的手性分离能力进行了评价和比较.考察了有机添加剂的种类和浓度,缓冲液的pH值等条件对10个手性化合物在两种CSP上手性分离的影响,计算得出了溶质在两种CSP上的手性选择性自由能差值,同时初步探讨了这些溶质在两种CSP上的手性识别机理.实验数据表明,氨基酸在TE上保留更强,但在TI-TE上得到了更好的手性分离效果.结果显示,经间甲基苯基异氰酸酯衍生化后的替考拉宁CSP在反相流动相中的分离能力有所提高.
A new HPLC chiral stationary phase (CSP), m-tolyl isocyanate teicoplanin (TI-TE), was synthesized from the macrocyclic glycopeptide teicoplanin CSP (TE), using a derivative agent, m-tolyl isocyanate. Evaluation and comparison of these two TE-based CSPs were carried out with 10 recemates, including 7 amino acids and 3 non-amino acid compounds (lamivudine, oxazepam and p-hydroxyphenylglycine), using RPLC mobile phase. The chromatographic results were given as the retention, selectivity, resolution factors and the enantioselective free energy difference corresponding to the separation of the two enantiomers. The effects of pH, organic modifier type and amount were discussed, and the stereoselectivities of the two TE-based CSPs were compared, and the chiral recognition mechanism of TE-based CSP was also discussed. The retention for a-amino acids on TE was somewhat longer than that on TI-TE while chiral selectivity and resolution were bigger on TI-TE. The results show that the derivative CSP gets better selectivity than TE CSP under the RP mode.