期刊文献+

基于Geant4的NaI(Tl)闪烁谱仪模拟 被引量:14

Simulation of NaI(Tl) Scintillation Spectrometer with Geant4 Toolkit
下载PDF
导出
摘要 Geant4是一套用于精确模拟粒子在介质中输运过程的蒙特卡罗数值计算软件工具包.本工作基于该工具包,通过对一个NaI(Tl)闪烁谱仪进行实例模拟计算,得到了与实验测量所得能谱具有相同特征的结果,表明Geant4不仅能够用于高能物理模拟,同时也可以应用于核技术领域的其它方面. Geant4 is a toolkit for accurately simulating the passage of particles through matter. A simulation of NaI(T1) scintillation spectrometer has been made with this toolkit and the calculated results of energy spectrum have the same characteristic with the spectrum measured in experiments. The work shows that Geant4 toolkit is not only suitable for high energy physical simulation, but also for other applications in nuclear technology field.
作者 程品晶 凌球
出处 《南华大学学报(自然科学版)》 2009年第3期1-4,共4页 Journal of University of South China:Science and Technology
基金 衡阳市科技局基金资助项目(2008KJ006)
关键词 Geant4工具包 蒙特卡罗方法 NaI(Tl)闪烁谱仪 核辐射探测 Geant4 toolkit Monte Carlo method NaI (TI) scintillation spectrometer detection of radiation
  • 相关文献

参考文献6

二级参考文献20

  • 1王月兴,马晓林,云昌全,曲善奎.压水动力反应堆燃料元件安全性的监测与分析[J].原子能科学技术,1996,30(4):307-311. 被引量:5
  • 2王月兴,马晓林,云昌全,曲善奎.用γ能谱分析法作元件破损实时监测中的影响因素[J].核电子学与探测技术,1996,16(5):345-349. 被引量:5
  • 3Miramonti Lino. A very low background HPGE detector operating deep underground at 4 800 m water equivalent[J]Applied Radiation and Isotopes, 2002,57 : 209-212.
  • 4Introduction to Geant4[EB/OL].http://www. a-sd.web.cern.ch/wwwasd/Geant4/G4UsersDocu-metsWelcome/IntroductionToGeant4/html/index.html. 2004.12.
  • 5Ljungvall J, Palacz M, Nyberg J. Monte Carlo Simulations of the Neutron Wall Detector System [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004, 528 (3): 741~762.
  • 6Ivanchenko VN. Geant4 Toolkit for Simulation of HEP Experiments[J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003, 502(2-3): 666~668.
  • 7Aichambault L, Beaulieu L, Carrier JF, et al. Overview of Geant4 Applications in Medical Physics[A]. Nuclear Science Symposium, Medical Imaging Conference[C].New York: IEEE, 2003. 1 743~1 745.
  • 8Truscott P, Lei F, Dyer C, et al. Geant4-a New Monte Carlo Toolkit for Simulating Space Radiation Shielding and Effects[A]. IEEE Radiation Effects Data Workshop[C].New York: IEEE, 2000. 147~152.
  • 9Physics Reference Manual[EB/OL]. http://ww-w.asd.web.cern.ch/wwwasd/Geant4/G4UsersD-ocuments/UsersGuides/PhysicsReferenceManual/html/PhysicsReferenceManual.html. 2004.12.