对董军航等人提出的多孔陶瓷膜层状结构模型进行了改进。比较了层高系数和单层膜平均孔径对模型计算的影响,结果表明采用单层膜平均孔径代替层高系数作为可调参数,孔径分布模拟结果有较明显的改善。
The laminate model of porous ceramic membranes proposed by Dong Junhang et al was modified.The mean pore size of the single stages was used as the adjustable parameter in this model instead of the k in the Dong′s work.Using this method, the PSD simulation results of alumina microfiltration membranes were improved.
出处
《南京化工大学学报》
1998年第3期96-99,共4页
Journal of Nanjing University of Chemical Technology(Natural Science Edition)
基金
国家九五科技攻关项目