期刊文献+

舵机动刚度试验台蓄能器的计算与分析

Calculation and Analysis of Accumulator for the Test of the Impedance of Hydraulic Booster Location System
下载PDF
导出
摘要 在舵机动刚度试验中,需要使用力伺服系统模拟外部大气干扰来测试舵机在高频负载力作用下的动刚度性能。而试验台泵站提供的瞬时流量无法达到高频大负载的油量要求,因此必须配置相应的蓄能器以补充瞬间供油量的不足。通过对蓄能器的容量计算,确定了满足试验要求的蓄能器型号及数量。 In the test of measuring for hydraulic booster location system, the loading system simulates atmospheric disturbance to test the performance of hydraulic booster location system in the case of instantaneous high frequency. But the instantaneous flux provided by pumping station of the test-bed can not satisfy the demand. So corresponding accumulator is used to reinforce instantaneous oil supply. The capacity of the accumulator was calculated, the appropriate type and number of accumulators that satisfy request of the test were choosed.
出处 《机床与液压》 北大核心 2009年第9期107-108,115,共3页 Machine Tool & Hydraulics
关键词 舵机动刚度 蓄能器 Hydraulic booster location system Accumulator
  • 相关文献

参考文献3

  • 1王鸿辉,吴娟,袁朝辉.舵机动刚度试验台研制分析[J].液压与气动,2004,28(11):1-3. 被引量:13
  • 2张家盛.舵机动刚度测控系统分析研究[D].西安:西北工业大学,2008.3.
  • 3王志明.气囊式动压蓄能器分析.DesignEngineer-ing,1989,35(3).

二级参考文献2

  • 1刘长年.液压伺服系统的分析与设计[M].北京:科学出版社,1987..
  • 2JeffreyRichter.Windows95程序设计指南[M],李书良译[M].台湾:基峰出版社,1997..