双波长共振光散射比率法及其在槲皮素分析中的应用

Dual-Wavelength Resonance Light Scattering Ratiometry and Its Application in Quercetin Analysis
下载PDF
导出
摘要 以槲皮素(QT)与Al^3+的相互作用为例,建立了基于单次扫描光谱获得共振光散射信号升降变化的一种全新双波长比率法.Al^3+在醋酸-醋酸钠缓冲溶液中形成的羟基配合物,随槲皮素加入,槲皮素将羟基配合物中的铝竞争下来形成槲皮素与铝的配合物,使得280nm处的散射强度(IRLS280)降低,444nm处的散射强度(IRLS444)增强.结果表明Log(IRLS^280/444nm)与槲皮素浓度在(2.5-25)×10^-5mol/L范围内呈线性关系,相关系数R=0.9980,检测限为2.0×10^-6mol/L. Using the interaction of quercetin (QT) with Al^3+ as an example, herein a dual-wavelength resonance light scattering (RLS) ratiometry was constructed for QT detection. In an acetate buffer solution, Al^3+ formed a hydroxy complex, and with the addition of QT, Al^3+ was contested from the hydroxy complex and preferential reaction between Al^3+ and QT occurred, displaying notable changes of RLS signals. Consequently, the RLS intensity of Al^3+ hydroxy complex at 280nm decreased, while the RLS intensity of Al^3+-QT at 444 nm was enhanced remarkably. It was found that Log (IRLS 280/444 nm) linearly deereased with the QT concentration over the range of 2.5-25 × 10^-5 mol/L, with a detection limit of 2.5 × 10^-6 mol/L.
出处 《西南大学学报(自然科学版)》 CAS CSCD 北大核心 2009年第9期120-123,共4页 Journal of Southwest University(Natural Science Edition)
基金 重庆市科委自然科学基金资助项目(CSTC 2008BB0248)
关键词 槲皮素 AL^3+ 双波长共振光散射比率法 quercetin (QT) Al^3+ dual-wavelength light scattering (LS) ratiometry
  • 相关文献

参考文献15

  • 1Crynkiewicz G, Poenie M, Tsien R. A New Generation of Calcium Indicators with Greatly Improved Fluorescence Properties [J]. Biol Chem, 1985, 260(9): 3440-3448.
  • 2Yang R H, Li K A, Wang K M, et al. Porphyrin Assembly on β-Cyclodextrin for Selective Sensing and Detection of a Zinc Ion Based on the Dual Emission Fluorescence Ratio [J]. Anal Chem, 2003, 75(3): 612 -621.
  • 3Yang R H, Chan W H, Lee A W, et al. A Ratiometric Fluorescent Sensor for Ag^1 with High Selectivity and Sensitivity [J]. J Am Chem Soc, 2003, 125(10) : 2884 - 2885.
  • 4Ueberfeld J, Walt D R. Reversible Ratiometric Probe for Quantitative DNA Measurements [J]. Anal Chem, 2004,76(4): 947 - 952.
  • 5Barco M, Planas C, Palacios O, et al. Simultaneous Quantitative Analysis of Anionic, Cationic, and Nonionic Surfactants in Water by Electrospray Ionization Mass Spectrometry with Flow Injection Analysis [J]. Anal Chem, 2003, 75(19): 5129-5136.
  • 6Xu H, Aylott J W, Kopelman R, et al. A Real-Time Ratiometric Method for the Determination of Molecular Oxygen Inside Living Cells Using Sol-Gel-Based Spherical Optical Nanosensors with Applications to Rat C6 Glioma[J]. Anal Chem, 2001, 73(17): 4124-4133.
  • 7Awaji T, Hirasawa A, Shirakawa H, et al. Novel Green Fluorescent Protein-Based Ratiometric Indicators for Monitoring pH in Defined Intracellular Microdomains[J]. Biochemical and Biophysical Research Communications, 2001, 289(2): 457 - 462.
  • 8Pasternack R F, Buatamante C, Collings P J, et al. Porphyrin Assemblies on DNA as Studied by a Resonance Light- Scattering Technique[J]. J AmChemSoc, 1993, 115(13): 5393-5399.
  • 9Asian K, Lakowicz J R, Geddes C D. Nanogold Plasmon Resonance-Based Glucose Sensing. 2. Wavelength-Ratiometric Resonance Light Scattering [J]. Anal Chem, 2005, 77(7): 2007- 2014.
  • 10Long Y J, Li Y F, Huang C Z, A Wide Dynamic Range Detection of Biopolymer Medicines with Resonance Light Scattering and Absorption Ratiometry [J]. Analytica Chimica Acta, 2005, 552(1): 175 - 181.

二级参考文献22

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部