摘要
介绍了天津站交通枢纽后广场地下主体结构采用盖挖逆作法施工对防水设防的要求,详细阐述了采用APF自粘卷材针对不同防水部位分别作满粘法施工和预铺反粘法施工的防水设计和工艺要求。
The article introduces the method of capped reverse application used in underground structure of Tianjin Railway Station Back Square and corresponding waterproofing requirements, details fully-adhered method and pre-laid stick side up method with APF sell adhered membrane.
出处
《中国建筑防水》
2009年第9期14-19,共6页
China Building Waterproofing
关键词
地下防水工程
盖挖逆作法
自粘防水卷材
满粘法
预铺反粘法
underground waterproofing project
capped reserve application
sell-adhered membrane
fully adhered
pre-laid stick side up method