在汽车空调制冷系统普通模糊控制基础上,引入了自组织模糊控制。采用双因子自校正模糊控制规则原理和汽车空调自组织模糊控制办法,并在不同压缩机转速下进行自组织模糊控制实验。表明自组织模糊控制较之普通模糊控制品质有所提高,表现为车室内温度过渡过程缩短,超调越小。
Based on the ordinary fuzzy control of automobile air conditioning system,this paper provides the self organizing fuzzy control(SOFC).The theory of multifactors self tuning fuzzy control and the concrete method of SOFC is discussed. The experiment using the SOFC under different velocities shows that it can get better control property in a shorter transitional period.