摘要
ZBD-68D型全数字电力线载波机具有全数字、智能化的特点,在安装调试及应用过程中,参数配置不当会出现各种类型的故障。文章简述了ZBD-68D型全数字电力线载波机的特点及其在电力系统中的应用,重点介绍了安装调试时常见故障及处理方法。
Because of the all-digital and intelligent characteristics,incorrect parameter configuration in ZBD-68D all-digital power line carrier can cause some faults during installation and testing.This paper discusses the principle of ZBD-68D all-digital power line carrier and its application in power system,analysed the common faults and introduces the trouble-shooting methods during equipment installation and testing.
出处
《电力系统通信》
2009年第9期69-72,共4页
Telecommunications for Electric Power System