摘要 移相控制ZVS PWM DC/DC全桥变换器是变换器的一个研究热点,诸如高性能、高效率、低噪声、低污染等理论问题急待研究。副边占空比丢失是移相全桥PWM DC/DC变换器中的一个重要现象,文章以移相全桥ZVS PWM DC/DC变换器电路模型为基础,结合变换器谐振电路的工作特点,对变换器副边占空比丢失的原因进行了详尽的分析,阐述了全桥变换器滞后臂比超前臂更难实现ZVS的原因,最终得到了移相全桥ZVS PWM DC/DC变换器死区时间和工作频率的设置条件与解决副边占空比丢失的措施。 Phase-shifting Full-bridge Zero-Voltage-Switch(PS- FB- ZVS) PWM DC/DC converter is a research notspot on converters. A lot of problems need to research urgently, such as high-performance, high efficiency, low noise, low pollution and so on. Secondary duty ratio loss is a very important phenomenon in PS- FB PWM DC/DC converter. In this article, on the basis of the circuit model of PS- FB- ZVS PWM DC/DC converter and combining the operating characteristic of resonant circuit, causes for secondary duty ratio loss of converter are analyzed in detail. The reasons of the lagging leg of FB converter achieving ZVS harder than the leading leg are also presented. Finally, setup conditions of dead-time and working frequency are obtained and measures to solve secondary duty ratio of PS- FB- ZVS PWM DC/DC converter are given.
出处 《通信电源技术》 2009年第5期47-49,共3页 Telecom Power Technology
关键词 占空比丢失 死区 ZVS 措施 duty ratio loss dead zone Zero-Voltage-Switching measures
  • 相关文献

参考文献3

  • 1张占松 蔡宣三.开关电源的原理与设计[M].北京:电子工业出版社,1999..
  • 2Denizar Cruz Martins, Fernando C Castaldo. Application of the ZVS-PWM Commutation Cell to a Full-Bridge DC - DC Converter[C]. IEEE Trans CAS-Ⅰ, 1999 .
  • 3Cho I G. IGBT based Zero Voltage Transition Full Bridge PWM Converter for High Power Applications[C]. IEE Proc. Electr. Power Appl, 1996.

共引文献97

同被引文献22

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部