摘要 针对传统磁通门传感器模拟电路温度性能相对较差的问题,研究了一种闭环数字磁通门传感器。利用高速A/D直接采样传感器信号,用单片机进行数字信号处理,再经D/A转换输出反馈信号。详细介绍了传感器的硬件结构和软件设计,并用该传感器对地磁场进行了测量试验。结果显示:它的零位温度系数为6.7×10-10/℃,灵敏度温度系数为2.5×10-4/℃,线性度达到了5.4×10-3。 Aimed at the poor thermal stability of traditional fluxgate sensor, a closed-loop digital fluxgate sensor is presented. The signal of fluxgate is sampled by high-speed A/D directly, handled by mierocontroller, and exported the feedback singal through D/A. The hardware structure and software design are described particularly. In order to test these methods, geomagnetic field measurements are carried out using this sensor. The results show that the zero temperature coefficient is 6.7 × 10^-1℃, the sensitivity temperature coefficient is 2.5 × 10^-4℃, the linearity reaches 5.4×10^-3.
出处 《传感器与微系统》 CSCD 北大核心 2009年第9期79-81,85,共4页 Transducer and Microsystem Technologies
关键词 数字磁通门传感器 温度系数 线性度 digital fluxgate sensor temperature coefficient linearity
  • 相关文献

参考文献3

  • 1Cerman A, Ripka P. Towards fully digital magnetometer[ J ]. Sensots and Actuators A ,2003 (106) :34--37.
  • 2Austert H U. Concept and first results of a digital fluxgate magnetometer[ J ]. Measurement Science and Technology, 1995 ( 6 ) : 477 --481.
  • 3张莹,刘诗斌,刘子懿.基于单片机的数字磁通门传感器[J].传感器与微系统,2006,25(7):46-49. 被引量:11

二级参考文献3

  • 1Henriksen P.Digital detection and feedback fluxgate mamagnetometer[J].Measurement Science and Technology,1996,(7):897-903.
  • 2Austert U.Concept and first results of a digital fluxgate mamagnetometer[J].Measurement Science and Technology,1995,(6):477-481.
  • 3刘诗斌,段哲民,严家明.电流输出型磁通门传感器的灵敏度[J].仪表技术与传感器,2002(9):4-6. 被引量:4

共引文献10

同被引文献54

  • 1石志勇,王怀光,庞发亮.磁通门信号处理电路分析与设计[J].兵工自动化,2006,25(6):82-83. 被引量:9
  • 2张莹,刘诗斌,刘子懿.基于单片机的数字磁通门传感器[J].传感器与微系统,2006,25(7):46-49. 被引量:11
  • 3李南,吕晓煜,岳喜展.微型磁通门传感器研究[J].电测与仪表,2007,44(2):57-59. 被引量:3
  • 4何静,李斌.基于二次谐波脉冲幅值法的磁通门传感器[J].传感器与微系统,2007,26(7):73-74. 被引量:8
  • 5Marchesi M, Melissano E, Morelli M, et al. An integrated micro-fluxgate magnetic sensor with front-end circuitry [J]. IEEE Sensors Journal, 2009, 58(9): 3269-3271.
  • 6Vannucci RC, Towfighi J, Vannucci SJ. Hypoxic preconditioning and hypoxic-ischemic brain damage in the immature rat:pathologic and metabolic correlates. J Neurochem,1998,71(3):1 215
  • 7Wick A, Wick W, Waltenberger J, et al. Neuroprotection by hypoxic preconditioning requires sequential activation of vascular endothelial growth factor receptor and Akt. J Neurosci, 2002,22(15):6 401
  • 8Miller BA, Perez RS, Shah AR, et al. Cerebral protection by hypoxic preconditioning in a murine model of focal ischemia-reperfusion. Neuroreport, 2001, 12(8):1 663
  • 9Chiappe-Gutierrez M, Kitzmueller E, Labudova O, et al. mRNA levels of the hypoxia inducible factor (HIF-1) and DNA repair genes in perinatal asphyxia of the rat. Life Sci, 1998,63(13): 1 157
  • 10Wiener CM, Booth G, Semenza GL. In vivo expression of mRNAs encoding hypoxia-inducible factor1.Biochem Biophys Res Commun, 1996,225(2):485

引证文献9

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部