期刊文献+

新型并联复合式超声波能量传输机构研究 被引量:1

Research on a New Composite Ultrasonic Energy Transmission Mechanism with Parallel Structure
下载PDF
导出
摘要 介绍了一种引线键合领域新型并联复合式超声波能量传输机构。与常规其他形式的超声波能量传输机构相比,用减弱了横向偏转刚度的夹持梁代替常规夹持环结构进行机构有效夹持,可显著降低并联结构的耦合特性。对一体式变截面三段变幅杆的杆长进行了优化设计,从理论上推导了复合振动平均能量密度公式。通过理论分析、有限元仿真及实验证明,此结构可有效提高振幅输出,增大超声波能量密度;通过调节双向振动参数在更大面积范围内完成原子键键合,从而减少键合时间,提高键合效率和强度。 This paper focuses on a kind of new composite ultrasonic energy transmission mechanism with parallel structure in wire bonding process. Compared with the traditional ultrasonic energy transmission mechanism, the new one replaces the conventional clamping ring with the clamping beam weakened the horizontal deflection stiffness, which can obviously reduce the coupling characteristics of the parallel structure. The length of the three-section amplitude-conversion pole with integration section-conversion is designed optimally and the average energy density formula of the composite vibration is theoretically derived. Through the theoretical analysis and experimental demonstration, it indicates that the parallel structure can increase the amplitude magnitude of the ultrasonic horn and the ultrasonic energy density, at the same time it can also perform the bonding to a large extent by adjusting the parameters of bidirectional vibration. Therefore, the bonding time is reduced and the bonding efficiency and strength are improved.
出处 《压电与声光》 CAS CSCD 北大核心 2009年第5期678-681,共4页 Piezoelectrics & Acoustooptics
基金 国家自然科学基金资助项目(50705027) "八六三"基金资助项目(2007AA04Z315)
关键词 引线键合 压电陶瓷 超声波换能器 wire bonding piezoelectric ceramics ultrasonic transducers
  • 相关文献

参考文献6

  • 1何田.先进封装技术的发展趋势[J].电子工业专用设备,2005,34(5):5-8. 被引量:13
  • 2PARRINI L. Advanced process characterization for 125 kHz wire bonder ultrasonic transducers[J].IEEE Transactions on Components and Packaging Technologies, 2002, 25(3):486-494.
  • 3LI Jun-hui, TAN Jian-ping, HAN Lei, et al. The characteristics of ultrasonic vibration transmission and coupling in bonding technology[C]. Shanghai: Institute of Electrical and Electronics Engineers Inc, 2004: 311-315.
  • 4陈新,李军辉,谭建平.引线键合中多向超声能量传输特性研究[J].制造技术与机床,2005(6):79-82. 被引量:1
  • 5TSUJINO J, FURUYA H, MURAYAMA Y. Detection of welding condition and welding characteristics of ultrasonic wire welding tip[C]. Electronics Eng bonding using a complex vibration Montreal: Institute of Electrical and Leers Inc, 1989:1 103-1 106.
  • 6TSUJINO J, HASEGAWA K, SONE Y, et al. Frequency characteristics of ultrasonic wire bonding using high frequency vibration system of 40 kHz to 780 kHz [C]. San Antonio: Institute of Electrical and Electronics Engineers Inc, 1996:1 021-1 026.

二级参考文献6

  • 1Tsujino, Jimmaru. Ultrasonic wire bonding using high frequency 330,600 kHz and complex vibration 190 kHz welding systems[ J] . Ultrasonics, 34 2 - 5 Jun 1996 Butterworth - Heinemann Lid :223 - 228 0041 -624X.
  • 2Jiromaru Tsujino, Hiroyuki Yoshihara, Tsutomu Sano and Shigeru Ihara. High - frequency ultrasonic wire bonding systems [ J ]. Ultrasonics,Volume 38, Issues 1-8, March 2000:77-80.
  • 3Jiromaru Tsujino, Hiroyuki Yoshihara, Kazuyoshi Kamimoto and Yoshiaki Osada. Welding characteristics and temperature rise of high frequency and complex vibration ultrasonic wire bonding[ J ]. Ultrasonics,Volume 36, Issues 1 - 5, February 1998:59 - 65.
  • 4J. Tsujino. Studies on Ultrasonic Wire Bonding [ J ]. WESTPAC Ⅲ,Shanghai China, Nov. 1988:207 - 210.
  • 5S. Y. Kang, P. M. William,T. S. Mclaren, Y. C. Lee. Studies of thermosonic bonding for flip - chip assembly [ J ]. Materials Chemistry and Physics,Volume 42, 1995:31 -37.
  • 6廖华丽,刘任先.功率超声变幅杆振动能量传输性能的研究[J].机械设计与制造,1999(5):71-72. 被引量:6