期刊文献+

200KA电解槽侧部炭砖破损原因及改善措施

200KA Electrobath Damaged Carbon Brick Side Causes and Improvement Measures
下载PDF
导出
摘要 电解槽寿命是电解铝厂的一项重要技术经济指标,我国槽寿命较短,主要原因是侧部早期破损,本文通过分析了200KA预备电解槽槽侧部炭砖破损严重的原因,总结了修补漏洞、降低电流、降低效应系数等措施,可有效改善侧部炭砖的破损度,减少侧部漏炉,确保了系列安全,有效降低了劳动量。 electrolytic electrolyzer plant life are an important technical and economic indicators, our country trough a shorter life expectancy, mainly due to early damage side, the paper prepared by analyzing a cell slot 200KA carbon brick side causes serious damage to sum up the vulnerability patch to reduce the current measures to reduce the effect coefficient, which can efecfively improve the carbon brick side of the broken, the furnace to reduce the side leakage to ensure that a series of safe, effective and reduces the amount of labor.
出处 《金属世界》 2009年第C00期66-68,共3页 Metal World
关键词 铝电解槽 侧部炭块 破损 改善措施 aluminum electrolytic tank side carbon block damaged improvement measures
  • 相关文献

参考文献4

  • 1杨重愚.轻金属冶金[M].北京:冶金工业出版社,1991.1~113.
  • 2邱竹贤.预焙槽炼铝(第三版).北京:冶金工业出版社.
  • 3现代大型预焙槽生产技术.沈阳:东北大学出版社.
  • 4杨重愚.氧化铝生产工艺.北京:冶金工业出版社,1990.