期刊文献+

高压电晕电场放电特性的研究 被引量:13

A Research on Characteristics of Corona Discharge
下载PDF
导出
摘要 研究了用于转基因的电晕电场在放电中针尖间距和针-板间距的变化对放电电流、放电输出功率和输出稳定性的影响.比较了多针-板与单针-板电晕放电的伏安特性.实验表明:针尖间距越大,电晕电流越大,当针尖间距大于20 mm时,电晕放电输出功率增长趋缓;当针尖间距为20 mm时,电晕放电可稳定输出较高的功率.针-板间距越小,电晕电流越大,当针-板间距为25 mm时,电晕放电输出功率最大. The current characteristics,discharge energy,and output stability of corona discharge for multi-needle plates are experimentally researched with the change of spacing between needles, and spacing of needle and plate. The current-voltage characteristics of a multi-needle plate and a single-needle plate for negative corona discharge are compared. Experimental results show that the needle-tip spacing is bigger,the corona current is bigger. When the needle-tip spacing is bigger than 20 mm,the corona discharge output growth becomes slower,and when the needle-tip spacing is 20 mm, the corona discharge may output a stable high power. The spacing of needle and plate is smaller, the corona current is bigger. When the spacing of needle and plate is 25mm,the corona discharge output is biggest.
出处 《内蒙古大学学报(自然科学版)》 CAS CSCD 北大核心 2009年第5期600-604,共5页 Journal of Inner Mongolia University:Natural Science Edition
基金 国家自然科学基金资助项目(50767002) 内蒙古自治区自然科学基金重大项目(200711020101)
关键词 电晕放电 放电输出功率 输出稳定性 corona discharge discharge output power output stability
  • 相关文献

参考文献5

二级参考文献21

共引文献31

同被引文献174

引证文献13

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部