期刊文献+

人体内金属植入物MR检查的安全性 被引量:4

Magnetic resonance safety:metallic implants and devices
下载PDF
导出
摘要 鉴于人体内植入物的复杂化和多样性,需要密切关注并尽可能的获取与MR检查环境相关材料的最新、最精确的信息。本文对MR检查的安全性、MRI与体内植入物的相互作用、各系统常用植入物研究的近况进行综述。 The variety and complexity of implants and devices change constantly and require continuous attention and diligence with regard to obtaining the most current and accurate information about these objects relative to the MR examination environment.MR safety,MR compatibility issues and presented important information for a variety of implants and devices were discussed in this review article.
出处 《中国介入影像与治疗学》 CSCD 2009年第5期485-488,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 磁共振成像 安全性 植入物 Magnetic resonance imaging Safety Implants
  • 相关文献

参考文献20

  • 1林曰增.临床MRI安全性的研究[J].国外医学(临床放射学分册),2000,23(1):19-22. 被引量:4
  • 2Baker KB, Tkach JA, Nyenhuis JA, et al. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. J Magn Reson Imaging, 2004,20(2):315-320.
  • 3Shafiei F, Honda E, Takahashi H, et al. Artifacts from dental casting alloys in magnetic resonance imaging. J Dent Res, 2003, 82(8) :602-606.
  • 4Shellock FG. Reference manual for magnetic resonance safety, implants, and devices: 2006 edition. Los Angeles: Biomedical Research Publishing Group, 2006.
  • 5陈宝峰,徐新.起搏器及植入型心律转复除颤器患者磁共振成像检查的安全性及相容性[J].中华心律失常学杂志,2007,11(1):75-78. 被引量:7
  • 6Shinbane JS, Colletti PM, Shellock FG. MR in patients with pacemakers and ICDs: defining the issues. J Cardiovasc Magn Reson, 2007,9(1) :5-13.
  • 7Hennemeyer CT, Wicklow K, Feinberg DA, et al. In vitro evaluation of platinum Guglielmi detachable coils at 3T with a porcine model: safety issues and artifacts. Radiology, 2001,219(3):732- 737.
  • 8Shellock FG. Magnetic resonance safety update 2002: implants and devices. J Magn Reson Imaging, 2002, 16(5) :485-496.
  • 9Kangarlu A, Shellock FG. Aneurysm clips: evaluation of magnetic field interactions with an 8.0T MR system. J Magn Reson Imaging, 2000,12(1) : 107-111.
  • 10Sawyer-Glover A, Shellock FG. Pre-MRI procedure screening recommendations and safety considerations for biomedical implants and devices. J Magn Reson Imaging, 2000, 12 (1) : 92 106.

二级参考文献57

  • 1戴永雨,张晶,高培毅,何志华.牙科金属对头部磁共振成像的影响[J].中华放射学杂志,1996,30(6):409-409. 被引量:4
  • 2Shellock FG,Crues JV 3rd.MR safety and the American College of Radiology White Paper.AJR,2002,178: 1349-1352.
  • 3Shellock FG,Tkach JA,Ruggieri PM,et al.Aneurysm clips: evaluation of magnetic field interactions and translational attraction by the use of ''long-bore'' and ''short-bore'' 3.0-T MR imaging systems.Am J Neuroradiol,2003,24: 463-471.
  • 4Shellock FG.Biomedical implants and devices: assement of magnetic field interactions with a 3.0-Tesla MR system.J Magn Reson Imaging,2002,16: 721-732.
  • 5Shellock FG.Magnetic resonance safety update 2002: implants and devices.J Magn Reson Imaging,2002,16: 485-496.
  • 6Sawyer-Glover A,Shellock FG.Pre-MRI procedure screening: recommendations and safety considerations for biomedical implants and devices.J Magn Reson Imaging,2000,12: 92-106.
  • 7Sommer T,Vahlhaus C,Lauck G,et al.MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T.Radiology,2000,215: 869-879.
  • 8Kangarlu A,Shellock FG.Aneurysm clips: evaluation of magnetic field interactions with an 8.0 T MR system.J Magn Reson Imaging,2000,12: 107-111.
  • 9Hug J,Nagel E,Bornstedt A,et al.Coronary arterial stents: safety and artifacts during MR imaging.Radiology,2000,216: 781-787.
  • 10Hennemeyer CT,Wicklow K,Feinberg DA,et al.In vitro evaluation of platinum Guglielmi detachable coils at 3 T with a porcine model: safety issues and artifacts.Radiology,2001,219: 732-737.

共引文献28

同被引文献29

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部