期刊文献+

个性化髋关节表面置换导航模板的设计与初步应用 被引量:4

原文传递
导出
摘要 髋关节表面置换术发展至今已有30余年历史。从第一代骨水泥假体固定技术和金属对聚乙烯的关节表面组合,到金属对金属假体的应用,髋关节表面置换术的成功率不断提高。髋关节表面置换术通过保留股骨头、颈恢复髋关节正常的生物力学特性及关节稳定性,与传统的全髋关节置换术相比脱位发生率低、关节活动度大、手术失血量少、深静脉栓塞发生率低、术后产生的磨损颗粒少,
出处 《中华骨科杂志》 CAS CSCD 北大核心 2009年第10期985-987,共3页 Chinese Journal of Orthopaedics
  • 相关文献

参考文献15

  • 1曾晖,刘国平,Michael Nogler,Martin Krismer.手术导航系统提高全髋关节置换术中髋臼假体植入精确度的研究[J].中华创伤杂志,2004,20(7):418-420. 被引量:14
  • 2Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg (Am), 1978, 60 (2): 217-220.
  • 3Daty PJ, Morrey BF. Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg (Am), 1992, 74(9): 1334-1343.
  • 4Kristiansen B, Jφrgensen L, Holmich P. Dislocation following total hip arthroplasty. Arch Orthop Trauma Surg, 1995, 103 (6): 375-377.
  • 5Choplin RH, Buckwalter KA, Rydberg J, et al. CT with 3D rendering of the tendons of the foot and ankle: technique, normal anatomy, and disease. Radiographics, 2004, 24(2): 343-356.
  • 6董建东,王友,朱振安,顾冬云,薛文东,戴尅戎.成人髋臼骨计算机三维重建及形态学测量[J].中华外科杂志,2005,43(24):1583-1586. 被引量:22
  • 7陈刚,杨静.全髋关节表面置换术的进展[J].中国修复重建外科杂志,2008,22(6):665-668. 被引量:8
  • 8张先龙,叶庭均,曾炳芳.髋关节表面置换技术新进展[J].中华外科杂志,2005,43(20):1355-1357. 被引量:24
  • 9Amstutz HC, Beaule PE, Dorey F J, et al. Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg (Am), 2004, 860): 28-39.
  • 10De Smet KA, Pattyn C, Verdonk R. Early result of primary Birmingham hip resurfacing using a hybrid metal-on-metal couple. Hip Int, 2002, 12(2): 158-162.

二级参考文献80

  • 1王琦,曾炳芳.髋关节表面置换术[J].国外医学(骨科学分册),2005,26(1):58-59. 被引量:23
  • 2王友,薛文东,董建东,史定伟.基于CAD软件的髋臼骨形态三维结构重建[J].医用生物力学,2005,20(1):42-44. 被引量:3
  • 3Schmalzried TP, Guttmann D, Grecula M, et al. The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg (Am), 1994, 76:677-688.
  • 4Kennedy JG, Rogers WB, Soffe KE, et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty, 1998, 13:530-534.
  • 5Bernsmann K, Langlotz U, Ansari B, et al. Computer-assisted navigated acetabulum placement in hip prosthesis implantation-application study in routine clinical care. Z Orthop Ihre Grenzgeb, 2000, 138:515-521.
  • 6Hassan DM, Johnston GH, Dust WN, et al. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty, 1998, 13:80-84.
  • 7Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg (Am), 1978, 60:217-220.
  • 8Daly PJ, Morrey BF. Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg (Am), 1992, 74:1334-1343.
  • 9Kristiansen B, Jorgensen L, Holmich P. Dislocation following total hip arthroplasty. Arch Orthop Trauma Surg, 1985, 103:375-377.
  • 10Hirakawa K, Mitsugi N, Koshino T, et al. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop, 2001, (388):135-142.

共引文献64

同被引文献64

引证文献4

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部