摘要
对比研究了用于加速度表标定的重力场、离心机与电模拟的三种方法,给出了在国内目前没有大g值精密离心机条件下,如何解决大量程(即大g值)加速度表的系数标定问题。
The three methods used in ca1ibration of accelerometer(gravity fie1d method,centrifuger method and electro-simulation method) have been compared and researched. Under the condition of that there is no accurate centrifuger with large measuring span(namely large g value) internally,the method of how to solve the problems of coefficient calibration of accelerometer with 1arge measuring span has been provided.
出处
《航空计测技术》
1998年第5期16-17,25,共3页
Aviation Metrology & Measurement Technology
关键词
加速度表
重力场
电模拟
离心机
系数标定
Accelerometer, Gravitational field, Electro-simulation, Centrifuger, Coefficient calibration