期刊文献+

节能建筑复合墙体热桥的二维非稳态传热

Research on Thermal Characteristics of Heat Bridges of Composite Wall in Energy saving Building
下载PDF
导出
摘要 采用有限元法对节能建筑复合墙体热桥进行二维非稳态传热分析。计算结果表明:冬季采用墙体外保温时墙体的重质承重部分和构造柱能够保持较高的内部温度,对建筑主体结构起到良好的保护作用,且热桥漏热损失小;内保温墙体由于保温层不连续,热桥部位的传热损失是外保温方式的3倍,采暖负荷计算时应该进行热桥传热修正,在我国北方热桥较多的小开间的采暖居住建筑中应慎重采用。 In this paper, finite element method has been utilized to analyze the unsteady thermal characteristics of heat bridges of interior and exterior composite wall insulation and their heat transfer losses of composite wall in energy saving buildings. The calculating result shows that heat loss of interior composite wall insulation's heat bridge is 3 times to exterior wall insulation; its heat load calculation must be correction with heat loss of heat bridge, and it must to be more careful in small fiat in north area.
作者 郁文红 杨昭
出处 《工程建设与设计》 2009年第10期40-43,共4页 Construction & Design for Engineering
关键词 建筑节能 复合墙体 热桥 有限元 energy saving building composite wall heat bridges finite element
  • 相关文献

参考文献4

二级参考文献15

  • 1龙惟定.上海的建筑节能与空调冷热源[J].暖通空调,1996,26(4):23-28. 被引量:35
  • 2涂逢祥.积极推进建筑节能,实施可持续发展战略[J].建筑节能,1996,(4).
  • 3许雷.高层建筑空调冷热源的能源及其对环境的影响.同济大学硕士学位论文[M].,1998..
  • 4-.《民用建筑热工设计规范》[M].北京:中国建筑工业出版社,1993..
  • 5GB50178-93.建筑气候区划标准[S].[S].,..
  • 6建设部建筑节能中心.促进我国建筑节能工作的建测[Z].上海:建筑节能研讨会,2001.
  • 7Siwei Lang, Yu Joe Huang. Energy conservation standard for space heating in Chinese urban residential buildings[J]. Energy,The International Journal, 1992, 18(8):871~892.
  • 8清华大学建筑环境与设备研究所.中国建筑节能调查分析报告[Z].2000.
  • 9许雷,硕士学位论文,1998年
  • 10孙明芳,能源研究与利用,1997年,2期