期刊文献+

基于番红花红聚合膜的生物传感器的应用研究 被引量:2

Study of biosensor and application of poly (safranine T) modified glassy carbon electrode
下载PDF
导出
摘要 研究了尿酸(UA)在番红花红(SFR)聚合膜修饰的玻碳电极上的电化学行为,发现SFR聚合膜电极对UA的氧化能够起到明显的电催化作用。分别利用循环伏安法(CV)、差分脉冲法(DPV)、计时电流法研究了UA在pH4.4的磷酸缓冲溶液中的线性关系,发现其浓度分别在2.0×10-5~9.0×10-4mol/L(CV),6.0×10-6~1.0×10-4mol/L、2.0×10-4~8.0×10-4mol/L(DPV),4.0×10-6~1.0×10-4mol/L(计时电流法)范围内呈良好的线性关系。该电极用于实际样品的测定,结果满意。 The electrochemical behavior of uric acid (UA) at poly (safranine T) modified electrode was investigated. It was found that the poly (SFR) modified electrode shows an obvious electrocatalytic activity for the oxidation of UA. In phosphate buffer(pH4.4), the linear relationship between peak current and concentration of UA was studied by the cyclic voltammetry (CV), differential pulse vohammetry (DPV), chronoamperometry method and the linear range for determination of UA was 2.0 ×10^-5- 9.0 ×10^-4mol/L(CV), 6.0 ×10^-4- 1.0×10^-4mol/L, 2.0 ×10^-4- 8.0 ×10^-4 mol/L(DPV), 4.0 ×10^-6- 1.0×10^-4 mol/L(chronoamperometry), respectively. The poly(SFR) modified electrode can be applied to the determination of UA in the practical injection samples with satisfactory results.
出处 《化学传感器》 CAS 2009年第3期61-65,共5页 Chemical Sensors
基金 河北省自然科学基金(C2007000813) 河北省卫生厅(08264)项目资助
关键词 番红花红 玻碳电极 尿酸 safranine T glassy carbon electrode uric acid
  • 相关文献

参考文献12

  • 1Thiagarajan S, Chen S M. Preparation and characterization of PtAu hybrid film modified electrodes and their use in simultaneous determination of dopamine, ascorbic acid and uric acid [J]. Talanta, 2007, 74: 212-222.
  • 2Behera S, Raj R. Mercaptoethylpyrazine promoted electrochemistry of redox protein and amperometric biosensing of uric acid [J]. Biosens Bioelectron, 2007, 23:556 - 561.
  • 3Liu A H, Honma I, Zhou H S. Simultaneous voltammetric detection of dopamine and uric acid at their physiological level in the presence of ascorbic acid using poly (acrylic acid)-multiwassed earbon-nanotube composite-covered glassy-carbon electrode[J]. Biosens Bioelectron, 2007, 23:74 - 80.
  • 4Wang G F, Meng J, Fang B. Determination of uric acid in the presence of ascorbic acid with hexacyanoferrate lanthanum film modified electrode [J]. Electrochim acta, 2008, 53:2 837 - 2 843.
  • 5Ohsaka T, Koichiro T. Electrocatalysis of poly (thionine)- modified electrodes for oxidation of reduced nicotinamide adenine dinucleotide [J]. J Chem Soc Chem Commun, 1993, 2:222 - 224.
  • 6Komura T, Ishihara M. Charge-transporting properties of electropolymerized phenosafranin in aqueous media [J]. J Electroanal Chem, 2000, 493: 84- 92.
  • 7Zhou D M, Sun J J. Electrochemical polymerization of toluidine blue and its application for the amperometric determination of 13-D-glucose [J]. Electrochim Acta, 1998, 43:1 803 - 1 809.
  • 8Selvaraju T, Ramaraj R. Simultaneous determination of ascorbic acid, dopamine and serotonin at poly (phenosafranine) modified electrode [J]. Electrochem Commun, 2003, 5:667 - 672.
  • 9Kearney P C, Mizoue L S. Molecular recognition in aqueous media. New binding studies provide further insights into the cation-π interaction and related phenomena [J]. J Am Chem Soc, 1993, 115:9 907 -9 919.
  • 10Li J, Lin X Q. Electrodeposition of gold nanoclusters on overoxidized polypyrrole film modified glassy carbon electrode and its application for the simultaneous determination of epinephrine and uric acid under coexistence of ascorbic acid [J]. Anal Chim Acta, 2007, 596:222 - 230.

同被引文献8

  • 1刘二保,卫洪清.化学发光法测定尿酸[J].光谱学与光谱分析,2005,25(8):1213-1215. 被引量:15
  • 2Thiagarajan S, Chen S M. Preparation and characterization of PtAu hybrid film modified electrodes and their use in simultaneous determination of dopamine, ascorbic acid and uric acid [J]. Talanta, 2007, 74: 212-222
  • 3Behera S, Raj R. Mercaptoethylpyrazine promoted electrochemistry of redox protein and amperometric biosensing of uric acid [J]. Biosens. Bioelectron., 2007, 23: 556-561
  • 4Liu A H, Honma I, Zhou H S. Simultaneous voltammetric detection of dopamine and uric acid at their physiological level in the presence of ascorbic acid using poly(acrylic acid)- muhiwalled carbon-nanotube composite-covered glassy- carbon electrode [J]. Biosens. Bioelectron., 2007, 23: 74-80
  • 5Park B W, Yoon D Y, Kim D S. Formation and modification of a binary self-assembled monolayer on a nano-structured gold electrode and its structural characterization by electrochemical impedance spectroscopy [J]. J Electroanal. Chem., 2011, 661: 329-335
  • 6Iwona S, Hanna R, Jerzy R, Roman K. Electrochemical impedance spectroscopy for study of amyloid 13 -peptide interactions with (-) nicotine ditartrate and (-) cotinine [J]. Biosens. Bioelectro., 2007, 22(9-10): 1955-1960.
  • 7张春梅,戴新华,杨屹,齐韬,方向.高效液相色谱法准确测定血清中的尿酸[J].分析试验室,2008,27(5):84-87. 被引量:12
  • 8周小棉,邹晓,王毅超.毛细管电泳测定尿中尿酸浓度[J].临床检验杂志,1999,17(4):220-221. 被引量:4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部