冷弯型钢骨架墙体抗剪性能研究 被引量:4

STUDY ON THE SHEAR PERFORMANCE OF COLD-FORMED STEEL FRAMING WALLS
原文传递
导出
摘要 在冷弯型钢骨架墙体抗剪模型得到试验充分验证的基础上,对影响墙体抗剪性能的8个因素进行了有限元参数分析。分析结果表明:墙体骨架壁厚、骨架屈服强度、立柱截面大小、竖向荷载大小的变化及一定范围内墙体高度的变化对墙体抗剪承载力影响不大;增加墙面板厚度可以有效地提高墙体抗剪承载力;在墙体尺寸等不变的情况下,立柱间距的减小有助于墙体抗剪承载力的提高;墙面板采用带肋钢板代替平钢板,在墙体抗剪承载力、墙板平面外鼓出量上均有很大的改进,并且随着肋高的增加,其抗剪承载力增加,墙板平面外鼓出量减小。 A parameter analysis of eight influencing factors of the shear performance of cold-formed steel framing walls is carried out after the finite element analysis model has been validated by test data. The analytic results show that it has little effect on the shear resistance of the wall by changing wall framing thickness, yield strength of wall framing, cross section of wall studs, vertical loading and altering the wall height in a certain range. The shear resistance of the wall can be improved effectively by thickening the wallboard; when the wall size is not changed, decreasing stud spacing is helpful to increase the shear resistance of the wall ; the shear resistance of the wall and the deformation out of plane of the steel panel can be greatly improved by substituting the steel rib panel for the smooth plate, and with the increase of the steel rib height, the shear resistanee of the wall is enhanced and the deformation out of plane of the steel panel is reduced.
出处 《工业建筑》 CSCD 北大核心 2009年第9期49-54,61,共7页 Industrial Construction
基金 <冷弯薄壁型钢结构技术规范>国家标准管理组专题研究项目
关键词 冷弯型钢骨架墙体 抗剪性能 有限元分析 cold-formed steel framing wall shear performance finite element analysis
  • 相关文献

参考文献8

二级参考文献56

  • 1[20]FEMA-273."NEHRP Guidelines for the Seismic Rehabilitation of Buildings",Prepared by the Building Seismic Safety Council for the Federal Emergency Management Agency,Washington,D.C.,1997.performance of wall 2.
  • 2[21]ECCS P88,European Recommendations for the Application of Metal Sheeting acting as a Diaphragm,Publication 88,European Convention for Constructional Steelwork,Brussels,1995.
  • 3[22]AISI,Shear Wall Design Guide,Publication RG-9804,The American Iron and Steel Institute,1998.
  • 4[23]Philip L,"Perforated Shear Wall Design",Wood Design Focus Vol.12,Nr.2,2002.
  • 5[24]Ekwueme G,Hart GC,"Non-linear Analysis of Light-Framed Wood Buildings",Proceedings of the 12th World Conference in Earthquake Engineering,Auckland,New-Zealand,February 2000.
  • 6[25]Della Corte G,De Matteis G,Landolfo R,"Influence of Connection Modeling on the Seismic Response of Moment Resisting Steel Frames",In F.M.Mazzolani (ed.) Moment Resistant Connections of Steel Frames in Seismic Areas,E & FN Spoon,2000.
  • 7[26]Prakash V,Powell GH,Drain-3DX Base program description and user guide,Version 1.10,Department of Civil Engineering,University of California at Berkley,1994.
  • 8[27]ENV-Eurocode 8,Design provisions for earthquake resistance of structures,1998.
  • 9[28]Vamvatsikos D,Cornell CA,"Incremental dynamic analysis",Earthquake Engineering and structural Dynamics,2002; 31(3):491-514,2002.
  • 10[29]ECCS (1983),P21-European Recommendation for Steel Construction:The Design and Testing of Connections in Steel Sheeting and Sections,ECCS,1983.

共引文献97

同被引文献49

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部