计算机断层扫描Z轴扫描位置的选取对患者所受有效剂量的影响 被引量:3

Influence of Effective Dose on Patients for Different Z Value During Computed Tomography
下载PDF
导出
摘要 目的:研究常规CT头部、胸部和腹部扫描过程中Z轴扫描位移对患者主要器官剂量及有效剂量的影响。方法:等间隔设置Z轴位移量,基于临床常用扫描参数,采用SR250软件估算患者器官剂量和有效剂量。结果:有效剂量产生规律性渐变,部分器官剂量对Z轴位移反应敏感。结论:在CT扫描过程中,可以有目的地避开或尽可能远离X射线敏感器官,以减小器官剂量,控制辐射风险。 Objective To investigate the influence of organ dose and effective dose on patients for different Z value during head, chest and abdomen CT scan. Methods With equispaced displacement on axis Z, organ dose and effective dose was estimated by using SR250 software with commonly used CT exposure parameters. Results Effective dose changed gradually for different Z value, some organ dose was sensitive to the Z location. Conclusion It is necessary to avoid X-ray sensitive organ in CT examination to minimize radiation risk.[Chinese Medical Equipment Journal,2009,30(9):5-6,13]
作者 刘彬 白玫
出处 《医疗卫生装备》 CAS 2009年第9期5-6,13,共3页 Chinese Medical Equipment Journal
基金 国家自然科学基金项目(30870751)
关键词 体层摄影术 X线计算机 辐射剂量 辐射监测 tomography X-ray computer radiation dosage radiation monitoring
  • 相关文献

参考文献10

  • 1郑钧正 贺青华 李述唐 等.“九五”期间全国医疗照射水平调查研究.中华放射医学与防护杂志,2000,20:2-7.
  • 2郑钧正,贺青华,李述唐,等."九五"期间全国医疗照射频率水平[J].中华放射学与防护杂志,2000,(增刊):14-18.
  • 3Imhof H, Schibany N, Ba-Salamah A, et ol. Spiral CT and radiation dose[J]. EJR, 2003,47:29-37.
  • 4United States Food and Drug Administration Center for Device and Radiological Health. Whole body scanning: using computed tomography(CT)[EB/OL]. (2009-04-23)[2009-04-25]. http://www. fda.gov/cdrh/ct.
  • 5International Commission on Radiological Protection, Publication 60:1990 Recommendations of the International ommission on Radiological Protection[M]. Oxford :Pergamon Press, 1990.
  • 6Shrimpton P C, Jones D G, Hillier M C,et al. Survey of CT practice in the UK:Part 2--Dosimetric aspects [M]. London: Chilton, 1991 : NRPB-R249.
  • 7Jones D G, Shrimpton P C. Survey of CT practice in the UK:Part 3--Normalised organ doses calculated using monte carlo techniques[M]. London : Chilton, 1991 : NRPB-R250.
  • 8Shrimpton P C, Edyvean S. CT scanner dosimetry: Report on a round table meeting establishing a survey of standard dosimetric measurements on CT scanners[J]. The British Journal of Radiology, 1998,71 : 1-3.
  • 9刘彬,白玫,费晓璐,魏岚.SR250软件在估算CT检查中患者器官剂量和有效剂量的应用[J].中国医疗设备,2008,23(6):14-16. 被引量:3
  • 10Miller D L, Baiter S, Wagner LK, et al. Quality Improvement Guidelines for Recording Patient Radiation Dose in the Medical Record[J]. J Vasc Interv Radiol,2004,15:423-429.

二级参考文献10

  • 1郑富强.放射治疗模拟技术的发展[J].医疗设备信息,2006,21(3):21-22. 被引量:3
  • 2郑钧正,贺青华,李述唐,等."九五"期间全国医疗照射频率水平[J].中华放射学与防护杂志,2000,(增刊):14-18.
  • 3[3]Imhof H,Schibany N,Ba-Salamah A,et al.Spiral CT and radiation dose[J].EJR 2003,Vol.47(1):29-37.
  • 4[4]Mathias Cohnen,Ludger W.Poll,Claudia Puettmann.Effective dose in standard protocols for multi-slice CT scanning[J].Eur Radiol 2003,13:1148-1153.
  • 5[5]1990 Recommendations of the International Commission on Radiological Protection,Annals of the ICRP 1991[S].ICRP Publication NO.60.Vol.21(1):17-37.
  • 6[6]Hongyu Jiang,Harald Paganetti,Herman Suit.A Case Study on Patient Effective Doses during Proton Radiation Treatment[J].American Nuclear Society,2005,4:17-21.
  • 7[7]S.HEIN1LICH,A.KELLER:Quasi-Monte Carlo methods in computer graphics,Part Ⅱ:The Radiance Equation[J].Technical Report,University of Kaiserslautern,1994,94:243-246.
  • 8[8]A.KELLER:A Quasi-Monte Carlo Algorithm for the Global Illumination Problem in the Radiosity Setting[J].Technical Report,University of Kaiserslautern,1994,94:260-267.
  • 9[9]Donald L.Miller,MD,Stephen Baiter,PhD,Louis K.Wagner,PhD,John Cardella,MD.Quality Improvement Guidelines for Recording Patient Radiation Dose in the Medical Record[J].Vasc Interv Radiol 2004;15:423-429.
  • 10郑钧正 贺青华 李述唐 等.“九五”期间全国医疗照射水平调查研究.中华放射医学与防护杂志,2000,20:2-7.

共引文献14

同被引文献26

引证文献3

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部