摘要
根据爆炸逻辑元件的作用原理,对爆炸零门及控制开关进行了设计,试验研究了不同结构、不同传爆药以及不同控制通道与传爆通道间隙下的零门功能,以及控制开关作用时间。结果表明:选择感度适中的细化HMX和较高爆炸能量的控制通道,在一定间隙下,爆炸逻辑元件能够完成自锁逻辑传爆功能;此外,应选择作用时间较短的控制开关,并注意其与起爆雷管的作用时间的匹配。
Based on the principle of explosive logic element, the explosive null gate and control switch were designed. The function of explosive null gate with different structure, different booster and different gap between control channel and detonation channel were tested, and the function time of different control switches were also measured. The results indicate that when the fined HMX with medium sensitivity and control channel with high explosive energy were selected, the detonation channel can be locked under certain gap condition. Meanwhile, the control switch with short function time should be selected, and the matching relationship of function time between the control switch and detonator shoule be noticed in the design.
出处
《火工品》
CAS
CSCD
北大核心
2009年第4期27-29,共3页
Initiators & Pyrotechnics
关键词
爆炸逻辑元件
爆炸零门
控制开关
作用时间
Explosive logic element
Explosive null gate
Control switch
Function time