期刊文献+

紫外吸收法水质监测的光信号探测与处理方法 被引量:1

Optical Signal Detecting and Processing For Water Quality Measurement System by Ultraviolet Absorption Spectrum
下载PDF
导出
摘要 在紫外光谱吸收法水质监测中,光信号的探测与处理是一项关键技术。利用双光路单通道循环分时采样方法,在软件控制下分时探测背景、参考、测量光强,消除了由于背景光的干扰和光源强度变化带来的影响,提高了监测系统的可靠性和精确性.并采用了双波段测量方式,用于消除水中浊度的影响,具有很强的实用性.用标准溶液进行了实验,相对标准偏差不超过1%,最大相对误差小于2.0%,说明系统有很高的精确性、准确性. In water quality measuring methods using ultraviolet spectrum absorption, optical signal detecting techniques are very important. The time-sharing sampling system is adopted to detect background light, reference light and measuring light with one dectector in double light, which can eliminate influences from the drift of source and background. The double wavelength band detection model can decrease the influence of turbidity in water. The techniques make the system more precise and reliable. The standard deviation is less than 1% and the maximum relative error is less than 2% for measurement of standard solutions. The results indicate that the precision and accuracy of the apparatus are good.
出处 《大气与环境光学学报》 CAS 2009年第5期393-400,共8页 Journal of Atmospheric and Environmental Optics
基金 中科院知识创新项目(030331)资助课题
关键词 水污染 吸光度 紫外光谱吸收法 信号探测与处理 water pollution absorbance ultraviolet absorbance signal detecting and processing
  • 相关文献

参考文献8

  • 1吴淑岱.水和废水监测分析方法指南[M].北京:中国环境科学出版社,1989:225-230.
  • 2Mrkva M. Automatic U.V.-control system for relative evaluation of organic water pollution [J]. Water Research, 1975, 9(5): 587-589.
  • 3Manool B A, Morgan P G. Organic pollutant monitor: USA 5420432 [P/OL]. 1995-05-30. http://www.patentstorm.us/patents/5420432.html.
  • 4王俊荣.COD_(Cr)测定废液中银的回收与利用[J].工业用水与废水,2005,36(3):16-18. 被引量:5
  • 5紫外(uV)吸收水质自动在线监测仪技术要求HJ/T191-2005[s].
  • 6李卫华.紫外吸收光度法测定化学需氧量(COD)方法与算法研究[D].合肥:中国科学院硕士论文,2003.
  • 7时红.水质分析方法与技术[M].北京:地震出版社,1993.
  • 8马惠昌,李选培,张斌.水体化学需氧量实时在线监测与EW-2100紫外吸收水质自动在线监测仪[J].分析仪器,2007(2):64-66. 被引量:6

二级参考文献10

  • 1国家环保局《水和废水监测分析方法》编委会.水和废水监测分析方法(第四版)[M].北京:中围环境科学出版社,2002.219-220.
  • 2Krisy J H. Removal of Silver and Mercury from spent COD test solutions [J]. water Pollution Control Federation,1984,56(5):468-473.
  • 3Gould J P. Recovery of Silver and Mercury from COD samples by Iron Cementation [J]. water Pollution Control Federation,1984,56(3):280-286.
  • 4GB11914-89水质化学需氧量的测定:重铬酸钾法.国家技术监督局,1989:1-4
  • 5Standard Methods for the Examination of Water and Wastewater,13th edition,Method no.220.1971:495
  • 6GB11892-89水质高锰酸盐指数的测定.国家技术监督局,1989:1-4
  • 7HJ/T132-2003高氯废水 化学需氧量的测定 碳酸钾高锰酸钾法.国家环境保护总局,2003-09-30
  • 8HJ/T100-2003高锰酸盐指数水质自动分析仪技术要求.国家环境保护总局,2003-03-28
  • 9American Public Health Association.Standard methods for the determination of water and wastewater-UV Absorbing organic constituents,1995:5-60
  • 10HJ/T191-2005紫外(UV)吸收水质自动在线监测仪技术要求.国家环境保护总局,2005-09-20

共引文献9

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部