基于脉冲漏磁理论的管道腐蚀缺陷宽度定量技术 被引量:7

Width Quantification of Corrosive Defect on Pipeline Based on Pulsed Magnetic Flux Leakage
下载PDF
导出
摘要 在带保温层管道腐蚀缺陷的定量检测中,缺陷的宽度定量是一项重要内容.提出了采用脉冲漏磁技术对带保温层管道的腐蚀缺陷进行检测.通过提取传感器峰值扫描波形中极值点的位置差ΔD作为特征量,分析了无保温层和带保温层情况下,ΔD随管壁腐蚀缺陷宽度的变化规律,从而得出了对管道腐蚀缺陷进行宽度定量的方法.实验结果证明了所采用方法的正确性和有效性. The width quantification is an important part in quantitative test of corrosive defect of the pipeline with insulation. We proposed a detecting method based on pulsed magnetic flux leakage (PMFL). ΔD, the position difference between the maximum and the minimum peak values in a scanning wave, is utilized as a feature to derive the corresponding relation between the ΔD and the width of defect. Accordingly, the method of width quantification is derived. And the validity of the new method is shown by experimental results.
出处 《测试技术学报》 2009年第5期390-395,共6页 Journal of Test and Measurement Technology
基金 国家科技支撑计划资助项目(2006BAK02B02)
关键词 脉冲漏磁 管道 腐蚀缺陷 定量 pulsed magnetic flux leakage pipeline corrosive defect quantification
  • 相关文献

参考文献6

  • 1李光海,沈功田,李鹤年.工业管道无损检测技术[J].无损检测,2006,28(2):89-93. 被引量:33
  • 2Ali Sophian, Gui Yun Tian, Sofiane Zairi. Pulsed magnetic flux leakage techniques for crack detection and characterization[J]. Sensors and Actuators A, 2006(125): 186-191.
  • 3Tian G Y, Sophian A. Study of magnetic sensors for pulsed eddy current techniques[J]. Insight, 2005, 47(5): 277- 279.
  • 4杨理践.管道漏磁在线检测技术[J].沈阳工业大学学报,2005,27(5):522-525. 被引量:36
  • 5康宜华,武新军.数字化磁性无损检测技术[M].北京:机械工业出版社,2006.
  • 6Yang Binfeng, Luo Feilu, Han Dan. Pulsed eddy current technique used for nondestructive inspection of aging aircraft[J]. Insight-Nondestructive Testing and Condition Monitoring, 2006, 48(7): 411-414.

二级参考文献11

共引文献74

同被引文献49

  • 1杨宾峰,罗飞路.脉冲涡流检测系统影响因素分析[J].无损检测,2008,30(2):104-106. 被引量:11
  • 2李莺莺,靳世久,魏茂安.管道漏磁法检测的ANSYS仿真研究[J].无损检测,2005,27(2):72-76. 被引量:21
  • 3曲志刚,靳世久,周琰.油气管道安全分布式光纤预警系统研究[J].压电与声光,2006,28(6):640-642. 被引量:15
  • 4杨光,李金国,苏兴荣.提高电涡流传感器可靠性试验和分析方法研究[J].电子测量与仪器学报,2007,21(2):35-39. 被引量:17
  • 5AL-NAEMI F I, HALL J P, MOSES A J. FEM modeling techniques of magnetic flux leakage-type NDT for ferro- magnetic plate inspections[J]. Journal of Magnetism and Magnetic Materials,2006,304:790-793.
  • 6DRURY J C, MARINO A. A comparison of the magnetic flux leakage and ultrasonic methods in the detection and measurement of corrosion pitting in ferrous plate and pipe [ C ]. 15th World Conference on Nondestructive Testing, 2000.
  • 7NESTLEROTH J B, BUBENIK T A. Magnetic Flux leak- age technology for natural gas pipeline Inspection [ P ]. Technical Report GRI-00/0180, Battelle, Topical Report to Gas Research Institute, 1999.
  • 8WILSON J W, TIAN G Y. Pulsed electromagnetic meth- ods for defect detection and characterization [ J ]. NDT & E Int. ,2007 (40) :275-283.