摘要
就某电厂75t/h循环流化床锅炉顶棚管发生爆管事故,从设计、安装、运行方面进行技术分析,并提出切实可行的整改措施,改进后在实践中解决了75t/h循环流化床锅炉顶棚管发生爆管事故,为企业节约生产成本取得了良好的经济效益.
The accident of the plant 75 t/h circulating fluidized bed boiler tube roof analyzed from the design,installation, operation technically,and feasible reform measures were put forward. This problem was solved in practice,saved production cost,and achieved better economic benefits.
出处
《宁夏工程技术》
CAS
2009年第3期260-262,共3页
Ningxia Engineering Technology
关键词
顶棚过热器
管道
爆管
质量流速
Roof superheater
pipeline
Cartridge igniter
mass flow