期刊文献+

球床模块式高温气冷堆在线燃耗测量系统准直器性能的Monte-Carlo分析 被引量:3

Performance Analysis of Collimator in Online Burnup Measurement System for Pebble Modular High-Temperature Gas-Cooled Reactor With Monte-Carlo Method
下载PDF
导出
摘要 针对球床模块式高温气冷堆(HTR-PM)燃耗测量系统的设计特点,利用Monte-Carlo模拟方法,分析球形体源测量中不同形式的限制束流的准直器的性能及其对燃耗测量的影响。结果表明,对HTR-PM在线燃耗测量,选择双锥孔准直器更为适宜。 The paper discusses the performance of different collimators with Monte-Carlo method and reveals their influence on the burnup measurement.The result shows that conical collimator is more appropriate for on-line burnup measurement.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2009年第9期813-816,共4页 Atomic Energy Science and Technology
关键词 燃耗测量 MONTE-CARLO法 燃料循环 球床模块式高温气冷堆 准直器 burnup measurement Monte-Carlo method fuel circulation pebble modular high-temperature gas-cooled reactor collimator
  • 相关文献

参考文献6

  • 1HAWARI A I, CHEN J W. Assessment of online burnup monitoring of pebble bed reactor fuel using passive gamma ray spectrometry[J]. IEEE Trans Nucl Sci, 2002, 49(3): 1 249-1 253.
  • 2LITaosheng, DONG Fang, ZHANG Liguo. The γ-spectra analysis for burnup measurement in HTR-PM[C] // The 2nd Asian and Oceanic Congress for Radiation Protection. Beijing: [s. n.], 2006: 263-266.
  • 3张立国,李桃生,方栋.球床式高温气冷堆在线燃耗测量中^239Pu的影响分析[J].核动力工程,2008,29(4):88-92. 被引量:5
  • 4BRIESMEISTER J F. MCNP--A general Monte-Carlo N-particle transport code (Version 4B), technical report LA-UR-O3-1987[R]. Los Alamos, US: Los Alamos National Laboratory, 2003.
  • 5TANG Chunhe, TANG Yiping, ZHU Junguo, et al. Design and manufacture of the fuel element for the 10 MW high temperature gas-cooled reactor[J]. Nuclear Engineering and Design, 2002, 218: 91-102.
  • 6李桃生,张立国,白晓平,谢腾飞.HPGe探测效率对照射野的依赖性[J].核电子学与探测技术,2007,27(4):624-627. 被引量:3

二级参考文献23

  • 1李桃生,方栋,李红,曹建主,胡守印.10MW高温气冷堆的燃耗测量研究[J].核电子学与探测技术,2006,26(2):129-131. 被引量:5
  • 2Abbas MI, Sealim Y. S. and Bassiouni M.. HPGe detector photopeak efficiency calculation including self absorption and coincidence corrections for cylindrical sources using compact analytical expressions [J]. Radiation Physics and Chemistry, 2001, 61:429.
  • 3Vidmar T, et al.. A semi-empirical model of the efficiency curve for extended sources in gamma-ray spectrometry[J]. Nucl Instrum Methods, 2001, A 470:533.
  • 4Karamanis D. Efficiency simulation of HPGe and Si(Li) detectors in τ-amd X-ray spectrosocopy[J]. Nucl Instrum Methods,2003, A 505:282.
  • 5Karamanis D, et al. Experimental and simulation efficiency of a HPGe detector with point-like and xtended sources[J]. Nucl Instrum Methods, 2002,A487:477.
  • 6Saegusaa J. , et al. Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples [J]. Applied Radiation and Isotopes, 2004, 61: 1383.
  • 7Ashrafi S. , et al. Pricise modeling of a coaxial HPGe detector[J]. Nucl Instrum Methods, 1999, A438:421.
  • 8Vargas MJ, et al. Efficiency transfer in the calibration of a coaxial p-type HPGe detector using the Monte Carlo method [J]. Applied Radiation and Isotopes, 2003,58 : 707.
  • 9Korun M, et al. Monte-Carlo calculation of the spatial dependence of the coaxialHPGe detector efficiency for point sources[J]. Nucl Instrum Methods, 1997, A390: 203-208.
  • 10Briesmeister JF. MCNP - A general Monte Carlo N-particle transport code. Report LA-7396-K, Version 3B, Los Alamos, CA (1986).

共引文献6

同被引文献22

  • 1李贵杰,李照永,张建民.碳氧比能谱测井基准问题的数值模拟[J].测井技术,2006,30(6):500-502. 被引量:11
  • 2Abbas M.I.,Sealim Y.S.,and Bassiouni M..HPGe detector photopeak efficiency alculation including selfabsorption and coincidence corrections for cylindrical sources using compact analytical expressions[J].Radiation Physics and Chemistry,2001,61(3-6):429-431.
  • 3Richard C.,Shawn M.B.,Robert D.W..Benchmarking computer simulations of neutron induced,gamma-ray spectroscopy for well logging[J].Applied Radiation and Isotopes,1997,48(10-12):1321-1328.
  • 4Jun Saegusaa,katsuya kawasaki,Akira Mihara,et al.Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume sampies[J].Applied Radiation and Isotopes,2004,61(6):1383-1390.
  • 5http://rsh.nst.pku.edu.cn/nuclide.
  • 6Briesmeister J.F.,MCNP-A general Monte Carlo N-particle transport code(Version 4B),technical report LA-UR-1987[R].Los Alamos,US:Les Alamos National Laboratory,2003.
  • 7Briesmeister J.F.,MCNP-A general Monte Carlo N-particle transport code(Version 4B),technical report LA-UR-1987[R].Los Alamos,US:Los Alamos National Laboratory,2003.
  • 8Richard C.,Shawn M.B.,Robert D.W..Benchmarking computer simulations of neutron induced,gamma-ray spectroscopy for well logging[J].Applied Radiation and Isotopes,1997,48(10-12):1321-1328.
  • 9LI T.S.,Dong F.,Zhang L.G.They-spectra analysis for bumup measurement in HTR-PM[C].The 2nd A sian and Oceanic Congress for Radiation Protection.Bejjing[s.n.] ,2006:263.
  • 10李桃生,张立国,白晓平,谢腾飞.HPGe探测效率对照射野的依赖性[J].核电子学与探测技术,2007,27(4):624-627. 被引量:3

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部