摘要
阐述了用于兰州重离子深层治癌装置的扫描电源的技术指标和工作原理,为保证该电源输出电流的精度,采用滞环控制策略,将跟踪误差限制在设计要求的误差范围内。研制了1台扫描电源样机,并给出了电路仿真和测试结果。测试结果显示各项指标均达到了设计要求,表明所选电路结构和滞环控制方案是切实可行的。
This paper describes the technique targets and operation principle of the scanning power supply for the deep tumor therapy facility with heavy ions in Cooler-Storage-Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR).To ensure the specified accuracy of the current,the hysteresis loop control strategy was adopted,and tracking error was constrained in the specified tolerance.One prototype was designed and installed.And the simulation results and test results were listed in the paper.The results show that all the targets can meet the design requirements,and that the circuit configuration and hysteresis loop control strategy selected are practicable.