摘要
结合具体工程实例,就框架结构常见渗漏部位作了归纳,重点从材料方面分析了引起外墙渗漏的原因,并有针对性地制定了一系列防治措施,通过这些措施的实施,收到了良好的防渗效果。
Combining with concrete project, the author concludes the common leakage parts of the frame structure, emphatically analyzes the causes of the exterior wall leakage from material aspect, and puts forward a serious of prevention measures, according to the implementation of these measures, gets good anti-seepage effect.
出处
《山西建筑》
2009年第31期128-129,共2页
Shanxi Architecture
关键词
框架结构
外墙渗漏
防治措施