探讨乳腺癌保乳术后调强放疗摆位误差的剂量学影响 被引量:3

下载PDF
导出
摘要 目的研究乳腺癌保乳术后调强放疗摆位误差对靶区内剂量的影响。方法使用电子射野影像系统(EPTD)在放疗初及放疗中对12例调强放疗的患者拍摄60辐射野图像,并与计划系统生成的标准射野数字重建图像(DRR)进行比较,测量每一位病人的平均摆位误差数值。比较每次调强放射治疗计划(治疗组)和参数误差纠正后制定的调强放射治疗计划(实验组)二者靶区剂量体积直方图差异。结果本组12例摆位误差在左右(x轴)和头脚(y轴)及前后(z轴)的平均移动误差分别为(0.8±6.2)mm、(3.4±4.2)mm和(1.7±1.2)mm。两组临床靶体积(CTV)的D95、V105%和V110%剂量经统计学处理无意义(P〉0.05)。结论乳腺癌就术后调强放疗PTV外放5mm是可行的。
机构地区 福建省肿瘤医院
出处 《实用肿瘤学杂志》 CAS 2009年第5期481-482,共2页 Practical Oncology Journal
  • 相关文献

参考文献2

  • 1Dischew, Sounders ML, Willamse, et al. Precision in reporting the dose given in a course of radiotherapy[J]. Radio ther Oncol, 1993,29 (3) :287 - 293.
  • 2Rutgvist L, Liedberg A,Hammar N,et al. Myocardial with conservative surgery and breast irradiation[J]. Int J Radiat Oncol Biol Phys, 1998,40(2) :359 - 368.

同被引文献26

  • 1Lingos TI, Reeht A, Vieini FA, et al. Radiation pneumonitis in breast cancer patients treated with conservative surgery and radiation therapy[J]. Int J Radiat Oncol Biol Phys, 1991, ( 2 ) : 355- 360.
  • 2Miehalski JM, Graham MV, Bosch WR, et al. Prospective clinical evaluation of an electronic portal imaging device [ J ]. Int J Radiat Biol Phys, 1996,34 (4) :943- 951.
  • 3赵缠均,亓芳迎,张玉丽,何晓丽,马小侠,朱姣.乳腺癌术后^(60)C_O放疗摆位的质量控制[J].现代肿瘤医学,2007,15(10):1499-1500. 被引量:1
  • 4ICRU. Reports 62 ICRU Publication[R]. Bethesda: ICRU, 1999:1097-1120.
  • 5Stroom JC, de Boer HC, Huizenga H, et al. Inclusion of geometricaluncertainties in radiother^jy treatment planning by means ofcoverage probability[J]. Int J Radiat Oncol Biol Phys, 1999,43(4):905-919.
  • 6Bahadur YA, Constantinescu CT, Hassouna AH. Significant inter-fraction variations during tangential breast irradiation. An indicationfor image-guided radiotherapy for simultaneously integrated boost[J].Saudi Med J, 2011, 32(3): 241-248.
  • 7Kim LH, Goyal S, Haffty BG, et al. Using respiratory motion toguide planning target volume margins for external beam partialbreast irradiation[J]. Int J Radiat Oncol Biol Phys,2012, 82(4):1303-1306.
  • 8Qi XS, White J, Rabinovitch R, et al. Respiratory organ motion anddosimetric impact on breast and nodal irradiation[J]. Int J RadiatOncol Biol Phys, 2010,78(2): 609-617.
  • 9van Mourik A, van Kranen S,den Hollander S, et al. Effects of setuperrors and shape changes on breast radiotherapy[J]. Int J RadiatOncol Biol Phys, 2011,79(5): 1557-1564.
  • 10Stiydhorst JH,Caudrelier JM, Clark BG, et al. Evaluation of athermoplastic immobilization system for breast and chest wallradiation therapy[J]. Med Dosim, 2011,36(1): 81-84.

引证文献3

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部