在长肢一字形截面柱极限承载力计算理论和假定的基础上,通过对六组构件的计算分析,得出了轴压比和墙肢截面高厚比对极限承载力的影响。
In this paper, research on theory of computation of ultimate bearing capacity is presented. By the calculation analysis of six sets of piece, axial load ratio and ratio of height to sectional thickness of wall have some influence to ultimate bearing capacity.