期刊文献+

单纯聚乙烯内衬更换在髋关节翻修手术中的应用 被引量:4

Simple polyethylene liner exchange in hip revision
原文传递
导出
摘要 目的探讨聚乙烯内衬磨损而髋臼金属杯仍然固定良好者进行单纯髋臼内衬更换的技术和疗效。方法瑞金医院在2003年2月至2007年3月期间,对16例HGⅡ型髋关节进行单纯内衬翻修手术,患者平均年龄63岁(51~82岁),距离初次手术时间平均6.2年(3~8年)。5例出现髋臼内衬脱位,3例出现髋臼金属假体周围骨吸收。术前Harris评分81.7分(56~91分)。所有患者术中取出磨损髋臼内衬后,清除髋臼内肉芽组织后,用骨水泥固定新的聚乙烯假体。3例假体周围骨吸收患者通过金属假体螺钉孔对缺损区域进行了异体骨打压植骨。结果16例髋关节术后随访2~6年,X线检查聚乙烯-骨水泥-金属杯界面没有松动迹象。3例髋臼金属杯周围植骨患者植骨愈合。随访中未发现感染及髋关节脱位。髋关节Harris评分87.6分(76~92分)。结论单纯聚乙烯内衬翻修具有手术操作简单、避免了金属杯取出继发髋臼骨缺损的优点。术后随访显示患者功能恢复良好、聚乙烯假体固定牢固。 Objective The purpose of this paper was to evaluate the surgical technique and the follow-up result of simple polyethylene liner exchange in well fixed metal shell.Methods Between Feburary 2003 to mar March 2007, 16 hips with a preexisting Harris-Galant Ⅱ acetabular socket that had been in situ for an average of 6.2 years (3-8 years) were revised with cementing and new polyethylene was inserted into a well fixed metal shell. Mean patient age was 63 years (51-82 years). Five hips presented a dislodgment of polyethylene liner and three hips who had osteolysis around the prosthesis component was performed a bone graft through the metal shell holes. Preoperative evaluation of Harris hip score was 81.7 (range 56-91).Results 16 patients were followed up for 2-6 years, all cases did not present polyethylene-cement-metal shell interface loosening in radiographic evaluation. 3 cases with allograft bone healing was found around the acetabular socket in three patients with allograft. No postoperative infection and dislocation was found in follow-up. The evaluation of Harris Score was 87.6 (range 76-92).Conclusions Simple polyethylene liner exchange is a safe and useful technique in patients with a stable meta shell, this technique preserves acetabular bone stock and permits a well fixation of new polyethylene insert.
出处 《中华关节外科杂志(电子版)》 CAS 2009年第5期2-4,共3页 Chinese Journal of Joint Surgery(Electronic Edition)
关键词 聚乙烯 内衬置换 关节成形术 置换 Polyethylene Liner exchange Arthroplasty replacement hip
  • 相关文献

参考文献1

二级参考文献7

  • 1[1]D'Antonio JA, Capello WN,Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthroplasty.Clin Orthop, 1989, 243: 126-137.
  • 2[2]Kelley SS. High hip center in revision arthroplasty. J Arthroplasty, 1994, 9:503-510.
  • 3[3]Sehutzer SF, Harris WH. High placement of porous-coated acetabular components in complex total hip arthroplasty. J Arthroplasty,1994, 9: 359-367.
  • 4[4]Dearborn J, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty.Results after a mean of ten years. J Bone Joint Surg Am, 1999,81: 469-480.
  • 5[5]Sutherland CJ. Early experience with eccentric acetabular components in revision total hip arthroplasty. Am J Orthop, 1996, 25:284-289.
  • 6[6]Lee BP, Cabanela ME, Wallrichs SL, et al. Bone-graft augmentation for acetabular deficiencies in total hip arthroplasty. Results of long-term follow-up evaluation. J Arthroplasty, 1997, 12: 503-510.
  • 7[7]Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am, 1997,79: 159-168.

共引文献1

同被引文献63

  • 1孙波,李瓦里,滕东辉,刘世珑.股骨颈骨折人工髋关节置换的偏心距调整[J].中国骨伤,2007,20(8):540-542. 被引量:2
  • 2BeauléPE,Ebramzadeh E,Le Du M,et al.Cementing a liner into astable cementless acetabular shell:the double-socket technique.J BoneJoint Surg(Am),2004,86-A(5):929-934.
  • 3Springer BD,Hanssen AD,Lewallen DG.Cementation of an acetabularliner into a well-xed acetabular shell during revision total hip arthro-plasty.J Arthroplasty,2003,18(7 Suppl 1):126-130.
  • 4Yoon TR,Seon JK,Song EK,et al.Cementation of a metal-inlay poly-ethylene liner into a stable metal shell in revision total hip arthroplas-ty.J Arthroplasty,2005,20(5):652-657.
  • 5Jiranek WA.Acetabular liner fixation by cement.Clin Orthop RelatRes,2003,(417):217-223.
  • 6Haft GF,Heiner AD,Dorr LD,et al.A biomechanical analysis of poly-ethylene liner cementation into a xed metal acetabular shell.J BoneJoint Surg(Am),2003,85-A(6):1100-1110.
  • 7Hofmann AA,Prince EJ,Drake FT,et al.Cementation of a polyeth-ylene liner into a metal acetabular shell:a biomechanical study.J Ar-throplasty,2009,24(5):775-782.
  • 8Meldrum RD,Hollis JM.The strength of a cement acetabular lockingmechanism.J Arthroplasty,2001,16(6):748-752.
  • 9Bonner KF,Delanois RE,Harbach G.Cementation of a polyethyleneliner into a metal shell.Factors related to mechanical stability.J BoneJoint Surg(Am),2002,84-A(9):1587-1593.
  • 10Kurtz S,Hozack W,Ray R.Biomechanical analysis of cementing anacetabular liner in a metal shell for revision total hip arthroplasty.Pre-sented at the Annual Meeting of the Orthopaedic Research Society,SanFrancisco,CA,2001.

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部