期刊文献+

800KVA±10%宽频发电机的设计和调试 被引量:1

Design and Debugging of 800KVA±10% Broad-frequency Generator
下载PDF
导出
摘要 在1FC5隐极同步发电机的基础上进行改型设计和调试,在THYRIPART励磁系统(不带调差装置)的基础上,去除电压整定器,增加励磁分流控制装置,就能满足宽频发电机的要求,使频率在40~60Hz之间变化时,输出电压在0.9~1.1UN之内变化。 On the basis of 1FC5 nonsalient pole synchronous generator, modified design and debugging are carried out, on the basis of THYRIPART excitation system (without droop compensation ), the requirements of broad-frequency generator can be met by removing reference-value selector and adding shunt excitation control device, output voltage is changed between 0.9 and 1.1 UN when frequency is changed between 40 and 60 Hz.
作者 卓陈祥 邓芳
出处 《船电技术》 2009年第10期16-21,共6页 Marine Electric & Electronic Engineering
关键词 宽频发电机 相复励励磁 自动电压调节器 励磁分流控制装置 Broad-frequency generator phase compound excitation automatic voltage regulator shunt excitation control device
  • 相关文献

参考文献3

  • 1Series 1FC5 Marine-type Brushless Three-phase Synchronous Generators Catalog[Z]. Siemens AG. 1993.
  • 2王宗德,朱水祥.1FC5系列发电机励磁系统简介[J].船电技术,1993(2):20-24. 被引量:2
  • 31FC5 506-6 TA92 发电机TRS F 28资料[Z].Siemens AG1984.

共引文献1

同被引文献7

  • 1GJB/Z299C-2006,电子设备可靠性预计手册[S].
  • 2Satyanarayana A, Prabhakar A. New topological formula and rapid algorithm for reliability analysis of complex networks[J]. IEEE Trans on Reliability,1978,27(2):82-100.
  • 3Abraham J A. An improved algorithm for network Reliability[J]. IEEE Trans on Reliability, 1979,28(1):58-61.
  • 4Tang J. Mechanical system reliability analysis using a combination of graph theory and Boolean function [J]. Reliability Engineering&System Safety, 2001,72(1):21-30.
  • 5昊麒.自动控制原理:上册[M].北京:清华大学出版社,1990.
  • 6张国志,杨振海,程维虎.基于最小路径与最小割集的复杂系统可靠性的描述与计算[J].数理统计与管理,2009,28(5):811-825. 被引量:5
  • 7李晓明,刘世琦,张翌晖.基于关联矩阵的变电所电气主接线可靠性分析[J].武汉水利电力大学学报,2000,33(4):35-38. 被引量:9