电除尘器强制收集系统设计计算 被引量:1

The Calculation and Design of Dust-collected System of ESP
下载PDF
导出
摘要 利用电场粉尘质量浓度分布理论式,计算静电除尘器模型断面粉尘质量浓度分布,证明了静电除尘器在收尘极板附近形成高质量浓度含尘气流区。为了提高电除尘器除尘效率,采用在电除尘器收尘极板末端用吸风口强制收集高质量浓度粉尘气流的方法,对强制收集的高质量浓度粉尘气流进行二级处理。并根据理论电场浓度分布可得到吸风高度与收尘效率的数学关系,最后通过能量守恒定律推导出吸风口均匀吸风时尺寸的计算方法。 By theoretical study,it is shown that dust concentration gradually increases from corona electrode to dust-collected wall inside electrostatic precipitators.The high-concentration gas flow is collected by the suction opening assembled at the end of ESP s plate and then gathered into high-efficiency bags or treated secondarily at the ESP inlet as the gas flow is cycled there.At the same time the dust-collected system can collect flying dust caused by shaking dust-collected wall.By analyzing flow function,the mathematical relationship between suction highness and dust - collected efficiency can be found out. Finally the calculation method of the inlet size is introduced by applying law of conservation of energy.
出处 《工业安全与环保》 北大核心 2009年第10期18-20,共3页 Industrial Safety and Environmental Protection
基金 国家高技术研究发展计划项目(2002AA642010)
关键词 浓度分布 除尘效率 强制吸收 电除尘器 dust distribution efficiency forced collection ESP
  • 相关文献

参考文献7

  • 1郝文阁.一种带有外循环系统的电除尘器及其应用方法.中国专利,200410050504.0.2004-09-24.
  • 2郝文阁,王宝军.ESP电场中高质量浓度区粉尘气流的强制收集技术[J].东北大学学报(自然科学版),2007,28(3):422-425. 被引量:6
  • 3Schmid H J,Stolz S, Buggisch H. On the modeling of the electro-hydrodyrnamic flow field in electrostatic precipitators. Flow, Turbulence and Combustion, 2002,68 (1) : 63 - 89.
  • 4Ullum T, Larsen P S, Ozcan O. Three - dimensional flow and turbulence structure in electrotatie precipitator by stereo PIV. Experiments in Fluids, 2004,36(1):91-99.
  • 5Leonard G, Mitchner M,Self S A. Particle transport in dectrostatic precipitators. Atmospheric Environment, 1980,14 ( 11 ) : 1 289 - 1 299.
  • 6Kallio G A, Stock D E. Interaction of electrostatic and fluid dynamic fields in wire- plate electrostatic precipitators. Huid Mech, 1992,240 (1):133- 166.
  • 7魏润柏.简明通风设计手册.北京:中国建筑工业出版社,1997.121-127.

二级参考文献8

  • 1龚立贤.电除尘器在国内火电厂的应用和设计要点.电除尘及气体净化,2001,7(3):10-14.
  • 2Ullum T,Larsen P S,Ozcan O.Three-dimensional flow and turbulence structure in electrostatic precipitatox by stereo PIV[J].Experiments in Fluids,2004,36:91-99.
  • 3Schmid H J,Stolz S,Buggisch H.On the modeling of the electro-hydrodynamic flow field in electrostatic precipitators[J].Flow Turbulence and Combustion,2002,68:63-89.
  • 4Ramadan O E,Soo S L.Electrohydrodynamic secondary flow[J].Physics ofFluids,1969,12:1943-1945.
  • 5Choi B S,Fletcher C A J.Turbulent particle dispersion in an electrostatic precipitator[ J ].Applied Mathematical Modeling,1998,22(12):1009-1021.
  • 6Leonard G,Mitchner M,Self S A.Particle transport in electrostatic precipitators[ J ].Atmospheric Environnent,1980,14:1289-1299.
  • 7Kallio G A,Stock D E.Interaction of electrostatic and fluid dynamic fields in wire-plate electrostatic precipitators[ J ].Fluid Mechanics,1992,240:133-166.
  • 8怀特.工业电收尘[M].王成汉,译.北京:冶金工业出版社,1984:349-352.

共引文献5

同被引文献4

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部