目的评价不同屏片组合下X线照片影像的颗粒性,以期掌握照片颗粒性的客观评价方法,并获得影响影像颗粒度的相关因素。方法利用显微密度计对测试样本进行扫描,通过均方根(rootmeansquare,RMS)值的计算,对不同屏片组合的X线影像进行颗粒度的物理评价。结果通过测试和数据整理,得出颗粒度与管电压、密度、对比度及清晰度的关系。结论X线照片影像颗粒度随着管电压、清晰度和对比度的升高而升高。
Purpose To evaluate granularity of X ray film in different screen film combinations and to learn the objective method of evaluating photo graininess and obtain relative factors that influence image granularity. Methods Using microdensitometer to scan the samples and calculating the root mean square (RMS) value, physical evaluation of X ray image granularity of different screen film combinations was made. Results Through measuring and calculating data , the relation of granularity versus tube voltage, photo density, contrast or definition was obtained. Conclusion Higher tube voltage, definition or contrast, lower density yield better X ray image graininess.
出处
《中华放射学杂志》
CAS
CSCD
北大核心
1998年第12期862-864,共3页
Chinese Journal of Radiology
关键词
X线胶片
X线增感屏
放射摄影术
X ray film X ray intensifying screens Radiography