离子选择性电极法测定磁性材料中微量氯离子 被引量:9

Determination of chloride in magnetic material by ion-selective electrode method
下载PDF
导出
摘要 建立了离子选择电极法测定磁性材料中氯离子的方法。以EDTA做掩蔽剂,加入柠檬酸三钠为总离子强度调节剂(TISAB),使离子活度系数相对稳定,pH值控制在5左右,用Gran氏作图法直接查得结果。对于氯含量低于0.02%的样品,采用标准加入法,并随同实验做实测能斯特斜率值,计算氯含量。该方法用于测定磁性材料中微量氯,相对标准偏差为8.1%,回收率为90%~105%。 An ion selective electrode method for the determination of micro-chloride ion in magnetic materials was developed. EDTA was used as masking agent, and trisodium citrate as total ion strength adjustment buffer (TISAB) was added to stabilize the ionic activity coefficient. The pH was controlled at about 5, the results were directly obtained by Gran graphing method. For the sample with chloride less than 0.02%, the standard addition method was used. The measured Nernst slope was employed to calculate the content of chloride ion. This method was applied to the determination of micro-chloride in magnetic materials with relative standard deviations (RSD) of 8.1%, and the recoveries of 90%--105 %.
出处 《冶金分析》 CAS CSCD 北大核心 2009年第9期66-68,共3页 Metallurgical Analysis
关键词 离子选择电极 磁性材料 ion selective electrode chloride magnetic material
  • 相关文献

参考文献7

  • 1GB/T12680.78-90稀土金属及其氧化物化学分析方法:硫氰酸汞-硝酸铁分光光度法测定氯量[S].
  • 2Orion Research. Analytical Methods Guide[M]. eigth edition, 1977.
  • 3GB10267.1-1988金属钙分析方法:氯离子选择性电极法测定氯[S].
  • 4中国计量科学研究院化学室.离子选择电极在北京地区深水分析中的应用.分析化学,1980,8(5):431-431.
  • 5上海化工学院成都工学院教研组,成都工学院分析化学教研组.分析化学(Analytical Chemistry)[M].北京:人民教育出版社,1979.
  • 6张义方,郭绍书,等.分析化学(Analytical Chemistry)[M].北京:高等教育出版社,1989.
  • 7S Tanikaml,etc. Anal. letters[M]. 1975.