期刊文献+

锁定加压接骨板治疗四肢骨折失败原因分析 被引量:1

下载PDF
导出
摘要 接骨板内固定是治疗四肢骨折的常用方法。锁定加压接骨板(locking compressioll plate.LCP)采用有限接触接骨板的设计模式,螺钉孔采用圆锥形螺纹锁定孔和动力加压孔一体化设计结构.为接骨板固定骨折提供了成角稳定性。笔者回顾性分析了自2006年9月至2009年2月采用LCP治疗四肢骨折120例患者的临床资料,其中7例内同定失败.从而探讨LCP在临床应用中的规范性操作问题。
出处 《实用医学杂志》 CAS 北大核心 2009年第19期3352-3353,共2页 The Journal of Practical Medicine
基金 霍英东青年教师基金资助课题(编号:81039)
  • 相关文献

参考文献8

  • 1Schutz M, Sudkamp N. Revolution in plate osteosynthesis:new internal fixator systems [J]. Orthop Sci ,2003,8(2) :252-258.
  • 2Kaab M J, Frenk A, Sehmeling A, et al. Locked internal fixator: Sensitivity of screw plate stability to the correct in sertion angle of the screw [J]. Orthop Trauma, 2004, 18(8) :483-487.
  • 3Borgeaud M, Cordey J, Leyvraz P E, et al. Mechanical analysis of the bone to plate interface of the LC-DCP and of the PC-FiX on human femora [J]. Injury,2000,31 (3) :29-36.
  • 4Schutz M, Muller M, Kaab M, et al. Less invasive stabilization system (LISS) in the treatment of distal femoral fractures [J]. Acta Chir Orthop Traumatol Cech,2003, 70(2) :74-82.
  • 5王爱民,赵玉峰,孙红振,杜全印,郭庆山,王子明,吴思宇,唐颖.点式接触解剖钢板内固定治疗不稳定性肱骨外科颈骨折[J].创伤外科杂志,2004,6(6):404-406. 被引量:16
  • 6Schutz M, Sudkamp N P. Revolution in plate osteosynthesis: new internal fixator system [ J ]. Orthop Sci, 2003,8 (2) : 252- 258.
  • 7Gautier E,Sommer C. Guidelines for the clinical application of the LCP [J]. Injury,2003,34 (2) : 63-76.
  • 8陈志伟,谭扬帆,戴祝,曹盛俊,廖瑛,李春.锁定加压接骨板内固定失败的原因分析[J].中华骨科杂志,2009,29(1):77-79. 被引量:23

二级参考文献14

  • 1Frigg R. Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Cmnpression Plate and the Point Contact Fixator (PC-Fix). Injury, 2001, 32 Suppl 2: 63-66.
  • 2Frigg R. Development of the Locking Compression Plate. Injury, 2003, 34 Suppl 2: B6-10.
  • 3Sommer C, Gautier E, Mtiller M, et al. First clinical results of the Locking Compression Plate (LCP). Injury, 2003, 34 Suppl 2: B43-54.
  • 4Wagner M. General principles for the clinical use of the LCP. Injury, 2003, 34 Suppl 2: B31-42.
  • 5Gautier E, Perren SM, Ganz R. Principles of internal fixation. Curr Orthop, 1992, 6: 220-232.
  • 6Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury, 2003, 34 Suppl 2: Bll-19.
  • 7Schutz M, Sudkamp NP. Revolution in plate osteosynthesis: new internal fixator systems. J Orthop Sci, 2003, 8: 252-258.
  • 8Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury, 2003, 34 Suppl 2: B63-76.
  • 9Niemeyer P, Sudkamp NP. Principles and clinical application of the locking compression plate (LCP). Acta Chir Orthop Traumatol Cech, 2006, 73: 221-228.
  • 10Namazi H, Mozaffarian K. Awful considerations with LCP instrumentation: a new pitfall. Arch Orthop Trauma Surg, 2007, 27: 573-575.