摘要
目的研究高血压病患者动态血压参数与颈动脉内-中膜厚度(CA-IMT)的关系。方法采用无创动态血压仪对127例高血压病患者进行24 h动态血压监测,同时应用高分辨率彩色多普勒超声显像仪测量患者颈动脉内-中膜厚度,据颈动脉内-中膜厚度分两组:CA-IMT≥0.9 mm为增厚组(n=53),CA-IMT<0.9 mm为正常组(n=74)。结果①CA-IMT增厚组与CA-IMT正常组的临床指标比较无统计学意义;②CA-IMT增厚组与CA-IMT正常组的动态血压参数比较:24 h平均收缩压(145.7±9.2)mmHg和(127.5±9.6)mmHg,24 h平均舒张压(83.5±5.1)mmHg和(76.7±5.6)mmHg,24 h脉压(62.3±10.1)mmHg和(47.8±9.5)mmHg;白天平均收缩压(148.6±6.3 mmHg)和(134.8±8.2)mmHg,白天平均舒张压(86.7±4.8)mmHg和(80.1±5.7)mmHg,白天脉压(63.5±10.9)mmHg和(51.4±9.1)mmHg;夜间平均收缩压(139.2±12.4)mmHg和(121.6±8.6)mmHg,夜间平均舒张压(79.3±9.0)mmHg和(70.3±5.2)mmHg,夜间脉压(60.1±11.7)mmHg和(50.4±7.1)mmHg,两者差异均有统计学意义(P<0.01)。CA-IMT增厚组与CA-IMT正常组其动态血压呈非勺型节律为54.7%比35.1%,其差异有显著性意义(P<0.05)。结论高血压病动态血压参数异常者颈动脉IMT增厚的发生率高,对靶器官损害有预测价值。
Objective To study the relationship between ambulatory blood pressure monitoring (ABPM) pa- rameters and carotid artery intima-media thickness(CA-IMT)in patients with hypertension. Methods One hundred and twenty-seven hypertensives including 89 males and 38 females were enrolled in this study . High resolution color Doppler uhrasonography was used to measure the CA-IMT,according to which the patients were classified into the in- creased IMT group(n= 53)or the normal IMT group(n= 74). Twenty-four hours ABPM were performed in all the pa tients. Results (1)There were no significant differences between clinical manifestations and biochemical parameters between the two groups ( P〉0.05). (2)The parameters of ABPM in the increased IMT group were higher than those in the non-increased IMT group. There were significant differences ( P 〈 0. 05) in 24h mean systolic blood pressure (145.7±9.2)mmHg vs. (127.5±9.6)mmHg,24h mean diastolic blood pressure(83.5±5.1)mmHg vs. (76.7±5.6) mmHg,24h pulse pressure(62.3±10.1)mmHg vs. (47.8±9.5)mmHg;daytime mean systolic blood pressure(148, 6 ±6.3 )mmHg vs. (134.8±8.2)mmHg, daytime mean diastolic blood pressure(86.7±4.8) mmHg vs. (80.1±5.7) mmHg, daytime pulse pressure (63.5±10.9)mmHg vs. (51.4±9.1)mmHgnighttime mean systolic blood pressure (139.2±12.4)mmHg vs. (121.6±8.6)mmHg, nighttime mean diastolic blood pressure(79.3±9.0)mmHg vs. (70. 3±5.2)mmHg,nighttime pulse pressure(60.1±11.7)mmHg vs. (50.4±7.1)mmHg;and the non-dippers rhythm of ambulatory blood pressure54.7% vs. 35.1%. Conclusion Among the hypertensives with abnormal ABPM parameters,the increased IMT are more often seen which could be prognostic value in estimating the degree of target organ damage in hypertension.
出处
《右江医学》
2009年第5期526-528,共3页
Chinese Youjiang Medical Journal
关键词
高血压
动态血压
颈动脉内-中膜厚度
Hypertension
Ambulatory Blood pressure monitoring
Carotid artery intima-media thickness