期刊文献+

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging 被引量:1

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging
原文传递
导出
摘要 X-ray diffraction sorbing low-Z sample. How enhanced imaging (DEI) is applied to extract phase information from to inspect internal structures of weakly abraw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is compared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. X-ray diffraction sorbing low-Z sample. How enhanced imaging (DEI) is applied to extract phase information from to inspect internal structures of weakly abraw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is compared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method.
出处 《Chinese Physics C》 SCIE CAS CSCD 2009年第11期969-974,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China (10875066, 30770618) Program for New Century Excellent Talents in University (NCET-05-0060)
关键词 diffraction enhanced imaging synchrotron radiation polynomial curve fitting diffraction enhanced imaging, synchrotron radiation, polynomial curve fitting
  • 相关文献

参考文献21

  • 1Davis T J, GAO D, Gureyev T E et al. Nature, 1995, 373: 595-598.
  • 2Chapman D, Thomlinson W, Arfelli F et al. Rev. Sci. Instrum., 1996, 67:3360 (published on CD-ROM).
  • 3Chapman D, Thomlinson W, Johnston R E et al. Phys. Med. Biol., 1997, 42:2015-2025.
  • 4Chapman D, Pisano E, Thomlinson W et al. Breast Disease, 1998, 10:197-207.
  • 5LIU Yi-Jin, ZHU Pei-Ping, CHEN Bo et al. Phys. Med. Biol., 2007, 52:L5-L13.
  • 6LIU Yi-Jin, ZHU Pei-Ping, CHEN Bo et al, Nucl. Instrum. Methods A, 2007, 580:617-620.
  • 7ZHU Pei-Ping, YUAN Qing-Xi, HUANG Wan-Xia et al. J. Phys. D: Appl. Phys., 2006, 39:4142-4147.
  • 8Bravin A. J. Phys. D: Appl. Phys., 2003, 36:A24-A29.
  • 9Michette A G, Buckley C J. X-ray Science and Technology, London, Institute of Physics publishing, 1993. 10-12.
  • 10Momose A, Takeda T, Yoneyama A et al. Analytical Sciences, 2001, 17:527-530.