期刊文献+

水轮发电机轴电流在线监测方案探讨 被引量:5

Discussion on Shaft Current On-line Monitoring of Hydro-generators
原文传递
导出
摘要 阐述了水轮发电机轴电流产生的原因和对发电机造成的危害,就目前在线监测水轮发电机轴电流的方法进行了深入分析。结合三峡工程700 MW水轮发电机轴电流在线监测的运行情况,分析了在线监测方案的优缺点,为进一步提高测量精度和监测水平提出了相应措施。并对水轮发电机如何选择配置轴电流监测方法给出了推荐意见。 The cause and harm of the shaft current to hydraulic generators are expatiated. The on-line monitoring methods of the shaft current at present are introduced. According to the practice of the shaft current on-line monitoring for the 700 MW hydraulic generator of the Three Gorges Project, the features of various shaft current on-line monitoring methods are analyzed,and corresponding measures to improve the precision and level of shaft current on-line monitoring are presented. Recommendations for selection and configuration of shaft current on-line monitoring are put forward.
作者 邹祖冰
出处 《水电自动化与大坝监测》 2009年第5期39-41,共3页 HYDROPOWER AUTOMATION AND DAM MONITORING
关键词 水轮发电机 轴绝缘 轴电流 在线监测 hydraulic generator shaft insulation shaft current on-line monitoring
  • 相关文献

参考文献7

二级参考文献24

  • 1王西田,于达仁,陈陈.汽轮发电机组轴系扭振的鲁棒非线性控制[J].电力系统自动化,2004,28(11):33-37. 被引量:6
  • 2刘素英,梁军,李欣唐,孙晓军.发电机功角微机测量及其应用[J].电力系统自动化,1993,17(10):42-46. 被引量:11
  • 3李刚,王少荣,夏涛,肖碧涛,程时杰,刘晓瑞.电力系统广域动态监测中的功角直接测量技术[J].电力系统自动化,2005,29(3):45-50. 被引量:28
  • 4兰洲,甘德强,倪以信.跟踪COI思想应用于多机系统励磁控制[J].电力系统自动化,2006,30(17):14-18. 被引量:19
  • 5张凯锋,戴先中,齐辉,赵大伟.复杂电力系统的元件结构化模型分析与应用[J].中国电机工程学报,2007,27(13):24-28. 被引量:12
  • 6AKHRIF O, OKOU F A, DESSAINT L A, et al. Application of a multivariable feedback linearization scheme for rotor angle stability and voltage regulation of power system. IEEE Trans on Power Systems, 1999, 14(2): 620-628.
  • 7BARRERA-CARDIEL E, PASTOR GOMEZ N. Microcontroller-based power-angle instrument for a power systems laboratory// Proceedings of IEEE PES Summer Meeting: Vol 2, July 18-22, 1999, Edmonton, Alberta, Canada, 1008-1012.
  • 8KEYHANI A, HAO S, DAYAL G. Maximum likelihood estimation of solid-rotor synchronous machine parameters from SSFR test data. IEEE Trans on Energy Conversion, 1989, 4 (3) : 551 558.
  • 9KYRIAKIDES E, HEYDT G T, VITTAL V. On-line estimation of synchronous generator parameters using a damper current observer and a graphic user interface. IEEE Trans on Energy Conversion, 2004, 19(3): 499-507.
  • 10DAI X Z, WANG W C, DINGY H, et al. “Assumed inherent sensor” inversion based ANN dynamic soft-sensing method and its application in erythromycin fermentation process, Computers & Chemical Engineering, 2006, 30(8): 1203 1225.

共引文献44

同被引文献23

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部