不同起搏方式对病窦综合征患者远期效果的影响 被引量:15

Effects of Alternative Pacing Mode on Cardiac Function of Patients with Sick Sinus Syndrome
下载PDF
导出
摘要 为了解不同起搏方式对病窦综合征特别是慢-快综合征患者心功能及房性心律失常的影响,利用超声心动图、体表心电图及Holter检查,对211例病窦综合征患者采用自身对照方法进行回顾性分析。结果发现:生理性起搏(AAI/DDD)组术后左室射血分数(LVEF)、心输出量(CO)明显增加(AAI:53.5±6.1%vs47.2±7.8%,4.95±0.57L/minvs4.20±0.62L/min;DDD:52.5±6.8%vs44.3±0.1%,5.12±0.71L/minvs4.41±0.38L/min;P均<0.01),左房内径(LAD)无明显变化;DDD组E/A比值明显增加(0.98±0.09vs0.87±0.15,P<0.01),AAI组E/A比值呈增加趋势(P=0.057)。房性心律失常发生率明显减少(15.9%vs50%,P<0.01)。非生理性起搏(VVI)组术后LVEF、CO明显下降(44.1±4.7%vs48.3±4.3%,3.77±0.42L/minvs4.17±0.85L/min,P均<0.01),LAD明显增大(39.26±2.37mmvs36.81±2.35mm,P<0.01),E/A比值呈? A retrospective analysis was made in 211 patients with sick sinus syndrome (SSS) by self control study.To assess the influence of alternative pacing mode on long term cardiac function and arrhythmia,several approaches including echocardiography,electrocardiogram (ECG) on torso surface and Holter were used.The results showed that:①The patients had higher left ventricular eject function (LVEF) and cardiac output (CO) after procedure of physiologic pacemaker implantation including AAI and DDD modes.The LVEF in group of AAI and DDD mode increased from 47.2 ±7.8 % to 53.5 ±6.1 % and from 44.3 ±0.1 % to 52.5±6.8% respectively ( P < 0.01 ).Likewise,the CO increased from 4.20±0.62 L/min to 4.95±0.57 L/min and from 4.41±0.38 L/min to 5.12±0.71 L/min respectively (P< 0.01 ).However,the left atrial diameter (LAD) had less change.The ratio of E/A increased obviously from 0.87±0.15 to 0.98±0.09 in DDD mode( P < 0.01 ) and was getting higher from 0.93±0.07 to 1.01±0.23 in AAI mode ( P =0.057).The incidence of atrial arrhythmia was much lower from 50% to 15.9%( P <0.01).② The group of patients with unphysiological pacemakers (VVI mode) had obviously decreased LVEF from 48.3 ±4.3 % to 44.1 ±4.7 % and CO from 4.17±0.85 L/min to 3.77±0.42 L/min,but more larger LAD from 36.81±2.35 mm to 39.26±2.37 mm( P <0.01).The ratio of E/A went down from 0.83±0.31 to 0.71±1.34.Although fewer atrial tachycardia happened than before,total incidence of atrial flutter and fibrillation increased from 49.6% to 56.6% ( P <0.05).Conclusion: Physiological pacemakers not only improved the long term cardiac function of patients with SSS,but also reduced atrial arrhythmia.Nevertheless,the patients with AAI pacemakers had no much better long term cardiac function than those with DDD pacemakers.
出处 《中国心脏起搏与心电生理杂志》 1998年第4期183-185,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
关键词 病窦综合征 心脏起搏 远期效果 起搏方式 Cardiac pacing,Physiological Cardiac function Arrhythmias,atrial
  • 相关文献

同被引文献60

引证文献15

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部