摘要 通过分析表明,冬季极度寒冷天气条件下工况环境温度的变化,是造成105 m^2带冷机投料运行初期出现链条脱齿现象的根本原因,介绍了整改办法和防范措施。对寒冷天气条件下保证设备的安全稳定运行具有良好地借鉴意义。 It is indicated by analyzing that The variety of temperature circumstance in working condition under the awful cold term in winter, it is result in that the chain disengages tooth while the cooling belt machine is working early days, And the method of amelioration and prevention is introduced. It is actively effect for how to ensure the machine running safetily under the coldly weather.
出处 《冶金信息导刊》 2009年第5期27-29,共3页 Metallurgical Information Review
关键词 链条 脱齿 环境温度 结构 对策 chain disengaging tooth surroundings temperature structure measure